The device is designed for 

single-phase installation 

and must be installed in 

accordance with standards 

valid in a particular country. 

The device should be con-

nected according to the de-

tails included in this operat-

ing manual. Installation, connection and control 

should be carried out by a qualified electrician 

staff, who act in accordance with the service 

manual and the device functions. 

In case of casing dismantling an electric shock 

may occur, and the guarantee is lost then. Be-

fore installation make sure the connection ca-

bles are not under voltage. The cruciform head 

screwdriver 3,5 mm should be used to instal the 

device. Improper transport, storage, and use of 

the device influence its wrong functioning. It is 

not advisable to instal the device in the following 

cases: if any device part is missing or the device 

is damaged or deformed. In case of  improper 

functioning of the device contact the producer.

CAUTION!

APPEARANCE

FEATURES

TECHNICAL DATA

DESCRIPTION

●  remote control of electric device opera-

tion by means of commands (incoming 

voice call, SMS massages) send from 

a mobile phone,

●  comfortable control of devices with dif-

ficult access (ventilation, heating, other),

●  three  operation  modes  (switching  on, 

switching off, restart - contact relay po-

sition change for adjusted time),

●  easy mounting in 230V AC socket,

●  operation  is  optically  signalled  (power 

supply, relay status, GSM modem status),

●  low  power  consumption,  possibility  of 

constant work.

GSM remote switch is used to control 

lighting, heating, etc., by means of GSM 

mobile (SMS massage and/or incoming 

mobile call). It is mounted in wall 230 V 

AC socket and it has the possibility of  

a remote restart of a connected device 

(relay status changes according to the ad-

justed time). The device has a wide range 

of protections as a list of numbers with 

permission, access password, etc. Its op-

eration range is limited only by GSM net-

work infrastructure and it is not equipped 

with operator’s lock (SIMLOCK). 

GRG-01

Input rated voltage: 230 V AC

Optic signalling of input rated voltage: LED green diode

Nominal power consumption: 0,5 W / 2,5 W (GSM operation)

GSM frequency: 900/1800/1900 MHz

Operation range: limited by GSM network structure

Signalling of GSM status: LED two-coloured diode (green)

Optic signalling of relay status: LED two-coloured diode (red)

Output contacts’ parameters: 1NO 16A / 250V AC AC1 4000 VA

Ambient temperature range: -10 ÷ +55 

o

C

Operating position: free

Casing mounting: 230 V AC socket

Casing protection degree: IP20 (EN 60529)

Protection level: II

Overvoltage category: II

Pollution degree: 2

Surge voltage: 1 kV (EN 61000-4-5)

Dimensions: 160 x 66 x 90 mm

Weight: 0,190 kg

Reference standard: EN 60950-1:2007 

EN 55024:2000

EN 61000-4-4

The symbol means selective 

collecting of electrical and electronic 

equipment. It is forbidden to put the 

used equipment together with  

other waste.

Optic signalling of input voltage

Optic signalling of GSM network 

status (green)

Receiver’s switch on optic signal (red)

Manual operation of the receiver

Programming push-button

Receiver’s socket

SIM card socket

Hole plug

Power supply pin

VER. 002_01.06.2011

SIM 

card

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: [email protected]

Отзывы: