background image

OWNER’S MANUAL

4" SUBMERSIBLE PUMP

Model PL-TE-10 – 1/2 HP, 10 GPM

Model PL-TE-20 – 1/2 HP, 20 GPM

Installation • Operation

Zabel Environmental Technology™

P.O. Box 1520

Crestwood, KY 40014

Z370 (Rev. 5/12/08)

LIMITED WARRANTY

4” Submersible pumps are warranted against defects in material and workmanship
for a period of 3 years from the date of original installation, not to exceed 42 months
from the date of manufacture, whichever occurs first. In no event shall Zabel be liable
for any consequential damages or any labor, material, freight or expense required to
replace, correct or reinstall the product. Zabel’s liability is limited to repair or replace-
ment of the part. All warranties are void if the product has been improperly modified,
applied or installed, subjected to misuse or abuse. Except as stated herein, there are
no warranties express or implied, including the warranty of merchantability or warranty
of fitness for a specific purpose.

Zabel Environmental Technology

TM

• P.O. Box 1520 • Crestwood, KY 40014

Содержание PL-TE-10

Страница 1: ...anufacture whichever occurs first In no event shall Zabel be liable for any consequential damages or any labor material freight or expense required to replace correct or reinstall the product Zabel s liability is limited to repair or replace ment of the part All warranties are void if the product has been improperly modified applied or installed subjected to misuse or abuse Except as stated herein...

Страница 2: ...been operated with discharge valve closed severe internal damage will result ELECTRICAL WIRING GROUNDING Can shock burn or cause death Permanently ground pump motor and control box before connecting power supply to motor Ground pump and motor in accordance with all codes and ordi nances that apply All wiring must meet National Electrical Code and Canadian Electrical Code whichever applies Use copp...

Страница 3: ...g lead The equipment grounding lead when provided will be the conductor having green insulation it may also have one or more yellow stripes C Ground the pump motor and any metallic conduit that carries power cable conductors Ground these back to the service by connecting a copper conductor from the pump motor and conduit to the ground ing screw provided within the supply connection box wiring comp...

Страница 4: ...tage is within 10 of rated nameplate If voltage variation is more than 10 call power voltage while motor is running company to adjust voltage High ambient atmospheric Check temperature of tank Protect tank from direct sunlight temperature Wire size too small Check wire size against chart Page 3 Install correct wire size Pump starts too frequently Leaks in system Check plumbing for leaks Level swit...