7.3 Set up the Terminal Window
(5) If you are running from a Windows PC, run TeraTerm. Select
“Setup – Serial Port” and set the
following:
Port:
Whichever serial port the port is connected to
Baud Rate: 115200
Data:
8-bit
Parity:
None
Stop:
1-bit
Flow Control: None
(6) If you are running from Linux, type:
# sudo minicom –s
And then configure by doing the following:
-Select “Serial Port Setup”
-Ensure the right Serial Device is specified (typically “/dev/ttyUSB0”)
-Set option E (“Bps/Par/Bits”) to 115200 8N1
-Press <return>
-Select “Exit”
7.4 Power on the board
(7) If using the board in standalone mode, connect the 12V power supply and turn on the switch. If using
the board in a PCI slot, insert it in the PCI slot if you haven’t already and turn on the host PC (note:
Hot-plug insertion and removal of the board is supported).
If all is configured properly, you should see the board booting up within the terminal window. After
about a minute, you will see the
RPS Main Menu (
).