background image

MANUAL • MANUEL • 

MANUAL

Z-Wave

®

 Certified Wireless Lighting Control

Certifié Z-Wave

®

 Commande d’éclairage sans fil

Control inalámbrico para iluminación certificado por Z-Wave

®

ezzwave.com

SPECIFICATIONS

ZW4007
Power: 120-277VAC, 60Hz, single phase
Signal (frequency): 908.4/916MHz 
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave 

receiver module 
Operating temperature range: -22 to 104° F (-30 to 40° C)
For outdoor use in dry, damp or wet locations
Contact ratings: 120-277VAC, 40A resistive single phase 

120-277 VAC, 20A ballast load (inductive) single phase 

125VAC, 15A tungsten  

250VAC, 5A tungsten 

1HP@120VAC,  

2HP @ 240VAC 

SPÉCIFICATIONS

ZW4007
Tension : Entre 120 et 277VCA, 60Hz, monophasé
Signal (fréquence) : 908.4/916MHz
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus 

proche allant jusqu’à 150 pi
Plage de températures de fonctionnement :  De -30 à 40° C (de -22 à 104° F).
Pour une utilisation extérieure dans des endroits secs, humides ou mouillés.
Caractéristiques nominales des contacts : Entre 120 et 277VCA, 40A de résistivité, 

monophasé
Entre 120 et 277VCA, 20A de charge de délestage (inductif), monophasé
125VCA, 15A tungstène
250 VCA, 5A tungstène
1HP à 120VCA
2HP à 240VCA

ESPECIFICACIONES

ZW4007
Electricidad: 120-277VCA, 60 Hz, monofásica
Señal (frecuencia): 908.4/916MHz
Alcance: Hasta 150 pies en línea recta entre el controlador inalámbrico y el módulo 

receptor Z-Wave más cercano. 
Rango de temperatura de funcionamiento: -30 a 40° C (-22 a 104° F)
Para uso en exteriores secos, húmedos o mojados
Regímenes nominales de contacto: 120-277VCA, monofásica resistiva 40A
120-277VCA, 20A balasto (inductivo) monofásica
125VCA, 15A tungsteno 
250VCA, 5A tungsteno
1HP@ 120VCA 
2HP@ 240VCA

• SE RECOMIENDA QUE LA INSTALACIÓN LA 

REALICE UN ELECTRICISTA AUTORIZADO.

PRECAUCIÓN

 

RIESGO DE DESCARGA ELÉCTRICA

• PUEDE QUE SEA NECESARIO DESCONECTAR 

MÁS DE UN INTERRUPTOR PARA 

DESENERGIZAR EL DISPOSITIVO ANTES 

DE REALIZAR EL MANTENIMIENTO.

• ALTA TENSIÓN (ES POSIBLE QUE HAYA MÁS 

DE UNA FUENTE DE ENERGÍA), DESCONECTE 

TODAS LAS FUENTES DE ENERGÍA ANTES 

DE REALIZAR EL MANTENIMIENTO.

• USE SÓLO CONDUCTORES DE COBRE.
• CIERRE LA TAPA DESPUÉS DE USAR.
• APRIETE LAS CONEXIONES A 25LBF-IN.
• USE CABLE DEL CALIBRE CORRECT  (8-

14AWG) TENIENDO COMO BASE EL CÓDIGO 

DE NORMAS DE ELECTRICIDAD LOCAL DE 

UN RÉGIMEN NOMINAL DE AL MENOS 80° 

C (CABLE MONOCONDUCTOR DE 8AWG).

• IMPERMEABLE, APROBADO PARA 

USO EN EXTERIORES.

• LONGITUD DE CABLE SIN 

AISLAMIENTO 1/2PULG.

CONEXIÓN A TIERRA

• EL CÓDIGO ESTADOUNIDENSE DE 

NORMAS DE ELECTRICIDAD EXIGE QUE LA 

PUESTA A TIERRA SEA CONTINUA, CON 

EL CONTACTO ELÉCTRICO ADECUADO EN 

TODOS LOS CONDUCTORES DE PUESTA 

A TIERRA, LAS CANALETAS METÁLICAS 

Y LOS BORNES DE PUESTA A TIERRA.

• RECOMMEND INSTALLATION BY 

LICENSED ELECTRICIAN.

CAUTION 

RISK OF ELECTRIC SHOCK

• MORE THAN ONE DISCONNECT SWITCH 

MAY BE REQUIRED TO DE-ENERGIZE 

THE DEVICE BEFORE SERVICING.

• HIGH VOLTAGE (THERE MAY BE MORE THAN 

ONE SOURCE OF SUPPLY) DISCONNECT ALL 

POWER SOURCES BEFORE SERVICING.

• USE COPPER CONDUCTORS ONLY.
• CLOSE THE COVER AFTER USE.
• TIGHTEN CONNECTIONS TO 25LBF-IN.
• USE CORRECT GAUGE WIRE (8-14AWG) 

BASED ON LOCAL ELECTRICAL CODE OF AT 

LEAST 80° C RATING (SINGLE CORE IN 8AWG).

• RAINTIGHT, APPROVED FOR OUTDOOR USE.
• WIRE STRIP LENGTH 1/2IN.

GROUNDING

• NATIONAL ELECTRICAL CODE REQUIRES 

GROUNDING MUST BE CONTINUOUS AND 

IN PROPER ELECTRICAL CONTACT IN ALL 

GROUNDING CONDUCTORS, METALLIC 

CONDUITS AND GROUNDING TERMINALS.

• INSTALLATION EFFECTUÉE PAR UN 

ÉLECTRICIEN QUALIFIÉ RECOMMANDÉE.

ATTENTION  

RISQUE DE CHOC ÉLECTRIQUE

• PLUS D’UN SECTIONNEUR PEUT ÊTRE 

NÉCESSAIRE POUR METTRE L’APPAREIL 

HORS TENSION AVANT UNE RÉPARATION.

• HAUTE TENSION (IL PEUT Y AVOIR PLUS 

D’UNE SOURCE D’ALIMENTATION), COUPER 

TOUTES LES SOURCES D’ALIMENTATION 

AVANT DE PROCÉDER À LA RÉPARATION.

• UTILISER SEULEMENT DES 

CONDUCTEURS DE CUIVRE.

• REFERMER LE COUVERCLE 

APRÈS L’UTILISATION.

• SERRER LES CONNEXIONS À 25LBF/PO.
• UTILISER UN FIL DU BON CALIBRE (8-14AWG), 

D’APRÈS LE CODE DE L’ÉLECTRICITÉ LOCAL, 

AYANT UNE TEMPÉRATURE NOMINALE D’AU 

MOINS 80° C (FIL UNIPOLAIRE 8 AWG).

• ÉTANCHE À LA PLUIE, APPROUVÉ 

POUR USAGE À L’EXTÉRIEUR.

• LONGUEUR DE FIL À DÉNUDER 1/2 PO.

MISE À LA TERRE

• SELON LE CODE NATIONAL DE 

L’ÉLECTRICITÉ, LA MISE À LA TERRE DOIT 

ÊTRE CONTINUE ET ASSURER UN CONTACT 

ÉLECTRIQUE ADÉQUAT SUR L’ENSEMBLE 

DES CONDUCTEURS DE TERRE, CONDUITS 

MÉTALLIQUES ET BORNES DE TERRE.

AVERTISSEMENT

WARNING

ADVERTENCIA

NOT FOR USE WITH MEDICAL OR 

LIFE-SUPPORT EQUIPMENT

Z-WAVE ENABLED DEVICES SHOULD 

NEVER BE USED TO SUPPLY POWER TO 

OR CONTROL THE ON/OFF STATUS OF 

MEDICAL OR LIFE-SUPPORT EQUIPMENT.

NE PAS UTILISER AVEC 

UN ÉQUIPEMENT MÉDICAL 

OU DE SURVIE

LES DISPOSITIFS COMPATIBLES 

AVEC LA TECHNOLOGIE Z-WAVE NE 

DEVRAIENT JAMAIS ÊTRE UTILISÉS 

POUR ALIMENTER OU COMMANDER 

LA MISE EN MARCHE OU L’ARRÊT DE 

L’ÉQUIPEMENT MÉDICAL OU DE SURVIE.

SE PROHÍBE SU EMPLEO EN 

EQUIPO MÉDICO O EQUIPO 

PARA EL MANTENIMIENTO DE 

LAS FUNCIONES VITALES

 

LOS DISPOSITIVOS Z-WAVE NUNCA 

SE DEBEN USAR PARA SUMINISTRAR 

ENERGÍA ELÉCTRICA AL EQUIPO MÉDICO 

O AL EQUIPO PARA EL MANTENIMIENTO 

DE FUNCIONES VITALES, NI PARA 

CONTROLAR EL ESTADO DE ENCENDIDO 

O APAGADO DE DICHOS EQUIPOS.

1/2in.

3/4in.

Getting to know your new Z-Wave device

•  Operation mode switch allows operation 

without requiring Z-Wave network

•  Remote ON/OFF control via the Z-Wave 

controller, on mobile devices 

•  Manual override ON/OFF control with 

the exterior-mounted push button 

•  Weather-resistant, rainproof housing; suitable 

for use outdoors in damp or wet conditions 

•  Lockable tamper-resistant metal case ensures 

secure connection and keeps dirt & debris out 

•  Energy monitoring capability allows remote monitoring 

of watts and kilowatt hours with compatible systems 

Tools you will need

1.

1.

A.  Indicator Lights

Red light

 — indicates smart switch is powered 

Green

 

light

 — indicates connected device is turned ON

B.  Manual Override Button

 

Single

 

press

 — turn the connected device(s) ON/OFF 

when operation mode switch is set to “Z-Wave

C.  Operation Mode Switch

 

ON

 — when set to “ 

 ” icon, the connected device 

has continuous power. Z-Wave control is disabled. 

 

OFF

 — when set to “ 

 ” icon, the connected 

device has no power. Z-Wave control is disabled. 

 

Z-Wave

 — when set to “ 

 ” icon, Z-Wave 

control is enabled. The connected device is 

controlled by Z-Wave and the front pannel.  

D.  Connection Terminal
E.  Programming Button
F.  S2 Security Label/SmartStart QR Code 

2.

2.

Pre-installation

Before installation, follow the instructions below to remove knockouts to route 

wiring to connection terminals. Knockouts may be made 1/2in. or 3/4in.

For 1/2in. knockout

1. 

Place a small blade screwdriver into inner ring of knockout circle as pictured above.

2. 

Tap down with the screwdriver to punch the 1/2in. knockout loose.

For 3/4in. knockout

1. 

Create 1/2in. knockouts as instructed.

2. 

With pliers, grip outer ring of knockout circle. 

3. 

Gently twist and pull to remove outer ring and form 3/4in. knockout.

3.

3.

4.

4.

WARNING — SHOCK HAZARD

Turn OFF the power to the branch circuit for the switch and lighting fixture 

at the service panel. All wiring connections must be made with the POWER 

OFF to avoid personal injury and/or damage to the switch. This device 

is intended for installation in accordance with the National Electric Code 

and local regulations in the United States or the Canadian Electrical Code 

and local regulations in Canada. If you are unsure or uncomfortable about 

performing this installation consult a qualified electrician.

Choose a suitable mounting location

Before you start, choose a location for mounting the 

box with the following considerations in mind:

1. 

RF range can be affected by obstructions, metal objects, distance 
and weather. Mount unit as close to the Z-Wave controller as possible. 

2. 

Mount in a location with at least 4in. of space above unit to allow 
space for antenna.

3. 

Install upright, in vertical orientation.

Mounting the box on drywall

1. 

H

old the box in place and use the three holes (highlighted 

above) to mark position on the mounting surface.

2. 

Drill a 3/16in. hole for the drywall anchors at each 
marked location. 

3. 

Insert an anchor in each hole. Gently tap the open end of 
anchor with a hammer until the anchor is flush with the wall. 

4. 

Align the smart switch with the anchors and secure it with  
the supplied screws. 

Mounting the box on plywood

1. 

Hold the box in place and use the three holes (highlighted above) 
to mark position on the mounting surface.

2. 

Drill a 3/32in. hole at each marked location. 

3. 

Mount the box to the surface using the three supplied #10 screws

.

IMPORTANT! 

Always close the rainproof door after use.

Antenna setup

1. 

Make sure the black antenna wire is routed through the externally  
threaded hole on top of the unit. 

2. 

A weather-resistant, black rubber antenna cover is included in top  
of the packaging. Place the antenna cover over the wire and screw  
down securely.

Connections

Terminal 1: 240V line 1 
Terminal 2: 240V line 2 

Terminal 3/5: Jumper connection 

between terminals 

Terminal 4: Load line 2
Terminal 6: Load line 1 

Connections

Terminal 1: 120V neutral/load 2 neutral
Terminal 2/5: 120V line/jumper 

Connection between terminals 

Terminal 3: Load 1 neutral
Terminal 4: Load 1 line
Terminal 6: Load 2 line

Connections

Terminal 1: 120V neutral
Terminal 2/5: 120V line/jumper 

Connection between terminals 

Terminal 3: Load 1 & 2 neutral
Terminal 4: Load 1 line
Terminal 6: Load 2 line

5.

5.

240VAC - Single Load Energy Monitored

120VAC - Single Load Energy Monitored

120VAC - Dual Load Load 1 Monitored

1

2

3

4

5

6

Load Line 2

Load Line 1

Jumper

Line 1

Line 2

Green/Bare

Ground

LOAD

1

2

3

4

5

6

Neutral

Neutral

Line

Line 

Green/Bare

Ground

LOAD

1

2

3

4

5

6

Neutral

Line

Neutral

Neutral

Line

Jumper

Line

Green/Bare

Ground

LOAD

LOAD

1

2

1

2

3

4

5

6

Neutral

Line

Neutral

Neutral

Line

Jumper

Line

Green/Bare

Ground

Neutral

LOAD

LOAD

1

2

120VAC - Dual Load Total of Both Loads Monitored

For proper wiring connections

1. 

Strip 1/2in. of insulation covering wires.

2. 

Tighten all screw terminals to 25lbf-in.

Note: 

Improper tightening can cause overheating and equipment failure.

Warning! 

Turn off power to the switch at the service panel.

Refer to “Warning – Shock Hazard” above.

3. 

Open metal enclosure door. Raise plastic guard covering terminals 1-6.

4. 

Input voltage connection

a. 

Connect 240VAC line 1 (black) to terminal 1.

b. 

Connect 240VAC line 2 (black) to terminal 2.

c. 

Connect ground wire (green/bare) to ground terminal.

5. 

Jumper connection

Connect jumper wire between terminals 3 and 5.

6. 

Load connection

a. 

Connect load Line 1 (black) to terminal 6.

b. 

Connect load Line 2 (black) to terminal 4.

c. 

Connect ground wires (green/bare) to ground terminal.

7. 

Lower plastic guard covering terminals 1-6. Close metal enclosure door.

8. 

Connection check

a. 

After 24 hours, disconnect power to module and check the connections.

b. 

Open metal enclosure door. Raise plastic guard covering terminals 1-6.

c. 

Verify all screws/connections are securely tightened.

9. 

Lower plastic guard covering terminals 1-6. Close metal enclosure door.

IMPORTANT: Always close rainproof door after use.

Connections

Terminal 1: 120V neutral  

Terminal 2: 120V line  

Terminal 3: Load neutral
Terminal 4: Load line

For proper wiring connections

1. 

Strip 1/2in. of insulation covering wires.

2. 

Tighten all screw terminals to 25lbf-in.

Note: 

Improper tightening can cause overheating and equipment failure.

Warning! Turn off power to the switch at the service panel. 

Refer to “Warning – Shock Hazard” above.

3. 

Open metal enclosure door. Raise plastic guard covering terminals 1-6.

4. 

Input voltage connection

a. 

Connect 120VAC neutral (white) to terminal 1.

b. 

Connect 120VAC line (black) to terminal 2.

c. 

Connect ground wire (green/bare) to ground terminal.

5. 

Load connection

a. 

Connect load neutral (white) to terminal 3.

b. 

Connect load line (black) to terminal 4.

c. 

Connect ground wires (green/bare) to ground terminal.

6. 

Lower plastic guard covering terminals 1-6. Close metal enclosure door.

7. 

Connection check

a. 

After 24 hours, disconnect power to module and check the connections.

b. 

Open metal enclosure door. Raise plastic guard covering terminals 1-6.

c. 

Verify all screws/connections are securely tightened.

8. 

Lower plastic guard covering terminals 1-6. Close metal enclosure door.

IMPORTANT: Always close rainproof door after use.

Adding your device

1. 

Follow the instructions for your Z-Wave certified controller to add a device to the 
Z-Wave network.

2. 

Once the controller is ready to add your device, press the programming button.  
If prompted by the controller to enter the S2 security code, refer to the QR code/
security number on the back of the box or the QR code label on the product. Enter 
the 5-digit code.

     

 

Note

: Your controller may need to be within 10ft. of the device to be added.

3. 

Once your controller has confirmed the device has been added, refresh the Z-Wave 
network to optimize performance.

You have complete control to turn your fixture ON/OFF according to groups, 

scenes, schedules and interactive automations programmed by your controller.

If your Z-Wave certified controller features remote access, you can control your 
fixture from your mobile devices.

 

To remove and reset your device

1. 

Follow the instructions for your Z-Wave certified controller to remove a device from 
the Z-Wave network.

2. 

Once the controller is ready to remove your device, press the programming button.

6.

6.

A

B

D

C

E

F

Z-WAVE INTEROPERABILITY

This product can be added and operated 
in any Z-Wave network with other Z-Wave 
certified devices from other manufacturers 
and/or other applications. All non-battery 
operated nodes within the network will 
act as repeaters regardless of vendor 
to increase reliability of the network. 

•  This device supports Association Command Class (3 Groups)
•  Association Group 1 supports Lifeline, Basic Report
•  Association Group 2 supports Basic Set and is controlled with the local load
•  Association Group 3 supports Basic Set and is controlled by pressing the  

Programming button

•  Each Association Group supports 5 total nodes

Example:

To return your device to factory defaults

14285  

ZW4007

READ IT 

OR

 WATCH IT

Read instructions or watch easy-to-follow video. 

Scan QR code or visit byjasco.com/14285i

Direct Wire 
Indoor/Outdoor

Smart Switch

À Raccordement Direct
Intérieur/Extérieur

Interrupteur Intelligent

Cable Directo
Para Interiores/Exteriores

Interruptor Inteligente

  

Fr

 
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils exempts 
de licence d’Industrie Canada. Son utilisation est sujette aux deux conditions suivantes : (1) cet 
appareil ne doit pas occasionner de brouillage préjudiciable et (2) cet appareil doit accepter toutes 
les interférences reçues, notamment les interférences qui peuvent provoquer un fonctionnement non 
désiré.

NOTE DE LA FCC :

 Le fabricant n’est pas responsable des interférences sur les fréquences 

radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de ce 
matériel. De telles modifications peuvent annuler le droit de l’utilisateur à utiliser cet appareil.

REMARQUE :

 Cet appareil a été testé et certifié conforme aux limites relatives aux appareils 

numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont été 
définies afin de fournir une protection raisonnable contre le brouillage préjudiciable en milieu 
résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et, s’il n’est pas 
installé et utilisé conformément aux instructions, il peut provoquer un brouillage préjudiciable aux 
communications radio. Il n’existe toutefois aucune garantie que des interférences ne se produiront 
pas au sein d’une installation donnée. Si cet appareil occasionne un brouillage préjudiciable à la 
réception radiophonique ou télévisuelle, il suffit d’allumer et d’éteindre l’appareil pour déterminer sa 
responsabilité. Nous encourageons l’utilisateur à essayer de corriger ces interférences en appliquant 
une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l’antenne de réception. 
— Augmenter la distance entre l’appareil et le récepteur. 
— Brancher l’appareil à une prise secteur différente de celle du récepteur. 
— Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC concernant 
l’exposition aux RF, aucune modification apportée à l’antenne ou au dispositif n’est autorisée. Toute 
modification apportée à l’antenne ou au dispositif pourrait faire en sorte que le dispositif dépasse les 
exigences d’exposition aux RF et pourrait annuler le droit de l’utilisateur à utiliser ce dispositif.

En

 
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS standards. 
Operation is subject to the following two conditions:  
(1) this device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation.

FCC NOTE: 

The manufacturer is not responsible for any radio or TV interference caused by 

unauthorized modifications to this equipment. Such modifications could void the user’s authority to 
operate the equipment.

NOTE: 

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy, and if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the interference by one or more of the following 
measures:
— Reorient or relocate the receiving antenna. 
— Increase the separation between the equipment and receiver. 
— Connect the equipment into an outlet on a circuit different from which the 
  receiver is connected. 
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements, no change to the 
antenna or the device is permitted. Any change to the antenna or the device could result in the 
device exceeding the RF exposure requirements and void user’s authority to operate the device.

Es

 

 
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC y con las 
especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria de Canadá aplicables 
a aparatos exentos de licencia. El funcionamiento está sujeto a las siguientes dos condiciones: (1) 
este dispositivo no debe provocar interferencia perjudicial, y (2) este dispositivo debe aceptar 
toda interferencia que reciba, incluso la que pudiera causar un funcionamiento no deseado.

NOTA DE LA FCC:

 El fabricante no se hace responsable de ninguna interferencia de radio 

o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas 
modificaciones podrían anular la autoridad del usuario para utilizar el equipo.

NOTA:

 Este equipo ha sido probado y cumple con los límites para aparatos digitales de Clase B, 

de conformidad con el apartado 15 de las normas de la FCC. Estos límites están diseñados para 
proveer protección razonable contra interferencias perjudiciales en una instalación residencial. Este 
equipo genera, usa y puede irradiar energía de radiofrecuencias y, si no se instala y usa según las 
instrucciones, puede provocar interferencia perjudicial a las radiocomunicaciones. No obstante, no 
hay garantías de que no ocurrirá interferencia en una instalación en particular. Si este equipo provoca 
interferencia perjudicial a la recepción de radio o televisión, lo que puede determinarse encendiendo 
y apagando el equipo, se recomienda que el usuario intente corregir la  
interferencia por medio de la implementación de una o más de las siguientes medidas:

—  Reorientar o reubicar la antena receptora.
—  Incrementar la separación entre el equipo y el receptor.
—  Conectar el equipo a un tomacorriente de un circuito diferente 

del circuito al que está conectado el receptor.

—  Consultar al distribuidor o a un técnico con experiencia en radio/televisión para  

solicitar asistencia.

Nota importante:

 Para cumplir con los requisitos de cumplimiento de exposición de 

radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier 
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de 
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.

Responsible Party - US Contact Information | Parte responsable - Información de contacto de los 
Estados Unidos | Partie responsable - Coordonnées des États-Unis

ZW4007:
FCC ID — U2ZZW4007 | IC: 6924A-ZW4007
Jasco Products Company | Model: ZW4007/14285 

10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483
CAN ICES-3(B)/NMB-3(B)

All brand names shown are trademarks 
of their respective owners. 
Tous les noms de marque illustrés sont des marques 
de commerce de leurs propriétaires respectifs.
Todas las marcas que aparecen aquí son marcas 
registradas de sus respectivos dueños.

MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA

JASCO PRODUCTS COMPANY LLC, 
10 E. MEMORIAL RD., OKLAHOMA CITY, OK 73114.

©JASCO 2020 | 14285 | ZW4007 | 12/22/20 v3

FCC/IC

DO NOT RETURN THIS 

PRODUCT TO THE STORE
NE RETOURNEZ PAS  

CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE  

PRODUCTO A LA TIENDA

STOP

If you have any problems or questions, contact our U.S.-based Consumer Care at 
1-800-654-8483, option 1, Monday–Friday, 7AM–8PM Central Time.
For the most up-to-date product support, accessories, electronic (PDF) 
format manuals and more, visit www.byjasco.com/support.
• No user-serviceable parts in this unit.
Si vous avez des problèmes ou des questions, veuillez communiquer avec notre  
service à la clientèle aux États-Unis au 1-800-654-8483, option 1, du lundi au  
vendredi, de 7 h à 20 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les accessoires, les manuels en 
format électronique (PDF) et plus encore, visitez le site www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l’utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro Centro de 
atención al cliente con sede en EE. UU. al 1-800-654-8483, opción 1 de 
lunes a viernes, de 7 a.m. a 8 p.m., hora estándar del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios, 
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.

WARRANTY

Jasco Products Company warrants this product to be free from manufacturing defects for five years from 

the original date of consumer purchase. This warranty is limited to the repair or replacement of this 

product only and does not extend to consequential or incidental damage to other products that may be 

used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states 

do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of 

incidental or consequential damage, so the above limitations may not apply to you. This warranty gives 

you specific rights, and you may also have other rights which vary from state to state. Please contact our 

U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7AM – 8PM, M-F, Central Time or  

www.byjasco.com if the unit should prove defective within the warranty period.

GARANTIE

Jasco Products Company garantit que ce produit est exempt de tout défaut de fabrication pendant une 

durée à cinq ans compter de la date de l'achat original par l'acheteur. Cette garantie se limite 

exclusivement à la réparation ou au remplacement de ce produit et n'est pas applicable aux dommages 

indirects ou accessoires survenus sur d'autres produits utilisés avec ce produit. Cette garantie se substitue 

à toute autre garantie expresse ou implicite. Certains États ne permettent pas de restrictions quant à la 

durée d'une garantie implicite ou permettent l'exclusion ou la limitation des dommages indirects et 

accessoires; il se peut, par conséquent, que cette garantie ne s'applique pas dans votre cas. Cette garantie 

vous confère des droits juridiques précis; vous pouvez jouir d'autres droits qui peuvent varier d'un État à 

l'autre. Veuillez communiquer avec notre service à la clientèle aux États-Unis au 1-800-654-8483 (option 

1) entre 7 h et 20 h, heure du Centre ou par l’intermédiaire de notre site web www.byjasco.com si l’appareil 

s’avère défaillant au cours de la période de garantie.

GARANTÍA

Jasco Products Company garantiza que este producto no tendrá defectos de fabricación por un cinco 

años a partir de la fecha de compr a del consumidor original. Esta garantía se limita a la reparación o 

reposición de este producto y no cubre daños indirectos o incidentales a otros productos que se pudieran 

utilizar con este producto. Esta garantía reemplaza cualquier otra garantía explícita o implícita. Algunos 

estados no permiten la aplicación de limitaciones respecto de la duración de una garantía implícita o 

permiten la exclusión o limitación de la cláusula sobre daños indirectos o incidentales, por este motivo las 

limitaciones arriba mencionadas pueden no aplicarse en su caso. Esta garantía le otorga derechos 

específicos y es posible que tenga otros derechos que pueden variar según el estado en el que vive. Por 

favor, comuníquese con nuestro Centro de atención al cliente con sede en EE. UU. al 1-800-654-8483 

(opción 1) entre 7 y 20 h, Hora del Centro, o a través de nuestro sitio de internet www.byjasco.com.

Jasco Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.

In-Wall 

Smart Dimmers

Plug-in 

Smart Dimmers

In-Wall 

Add-on Switches

Purchase additional items at 

EZzwave.com or visit your local retailer.

In-Wall   Motion 

Switch or Dimmer

Plug-in 

Smart Switches

In-Wall 

Smart Switches

Enbrighten  

Smart LED Bulb

In-Wall 

Smart Fan Control

Hinge Pin 

Smart Door Sensor

Portable 

Smart   Multi 

 Sensor

In-Wall 

Tamper-Resistant  

Smart Outlet 

Plug-in

Outdoor Smart 

Switch

DSK/PIN CODE

DSK  :   

XXXXX

 

-25651-22671

 

-26939-47599

 

-19612-25872

 

-47752

NOTE

SmartStart enabled products can be added into a Z-Wave network by scanning the  

QR code on the product with a controller providing SmartStart inclusion. No further action is  
required and the SmartStart product will be added automatically within 10 minutes of being  
switched on in the network vicinity.

1. 

Place device into ON mode (upper position of operating mode switch)

2. 

Press and hold the programming button.

3. 

While holding programming button, place device into OFF mode (middle position 
of operating mode switch).

4. 

While holding programming button, place device back into ON mode (upper 
position of operating mode switch). 

5. 

After three seconds, release programming button. Green LED will flash five times 
when completed.

Note: This should only be used in the event your network’s primary controller is 

missing or otherwise inoperable.