Standard System Components
Standard primary components of the NJEX-8300G
include the following:
•
System Enclosure
,
figure 1
. Houses the Model
8000F pump, the Model VM-2100 Verometer, the
odorant fill valve, the solenoid valve/pneumatic relay
manifold, the odorant discharge manifold, the system
control enclosure, power supply enclosure*, and bulk
odorant filter.
•
SPS12 Solar Panel Assembly
,
figure 1
. The stan-
dard solar panel for the 8300G is equipped with a
mounting bracket and a connection cable.Optional
LPS-120/240 may be used in lieu of the solar panel*.
•
System Control Enclosure
. Houses the N-300G
controller. (Not illustrated)
•
*Power Supply Enclosure
. Houses the battery,
charger supply, and I.S. Barrier. (Not illustrated)
•
Bulk Odorant Filter
,
figure 3
. Provides primary
odorant filtration between the storage tank and the
NJEX-8300G. The Bulk Odorant Filter is pre-installed
inside the System Enclosure attachment to the
odorant source is via an odorant inlet manifold
equipped with 1/4" FNPT connection located on the
back of the System Enclosure.
•
Service Tray,
(Not Illustrated),
should be installed in
the bottom of the system enclosure, to capture any
drops that may occur during servicing of the odorizer.
•
Mechanical Cabinet Cable
,
figure 3
. Provides the
connection between the system control enclosure and
the electrical components in the mechanical section.
•
Expansion Tank
,
figure 2
. Provides a closed loop
system for pressure fluctuations within the Verometer
during the odorant fill/injection cycle.
•
NJEX Gas Filter
,
figure 2
. Installed between the
actuation gas regulator and the actuation gas mani-
folds, this filter provides a 25 micron coalescent
filtration to insure a clean pneumatic supply.
•
Actuation Gas Regulator
,
figure 3
. Provides
additional regulation of supply gas to actuate the pump.
Figure 2
System Enclosure
Figure 1
• SPS12 Solar Panel Assembly
Expansion
Tank
NJEX Gas
Filter
Figure 3
Bulk Odorant Filter
Actuation Gas Regulator
* ATEX installations refer to Appendix E. page 117.