Setting Operator Input Parameters,
Continued
Max gas flow in Gal/min (liters/min)
Max gas flow is the maximum flow rate at which the
flow input reaches full scale span.
To set the max gas flow,
figure 40, press and release
the Select key. The value entry will begin to flash when
selected. Use the Up Arrow key to increase the value
and the Down Arrow key to decrease the value. When
a new value has been chosen, press the Enter key to
store the new value into memory. The entered value will
stop flashing when it has been loaded into the memory.
Press the Down Arrow key to advance to the next
parameter.
The low flow shut off setting,
allows a preset point in
a percentage of max gas flow desired to the N-300
to stop injecting odorant. This allows the controller
to sense low flow conditions where the operation is
not desired. This setting will override the max time /
stroke setting parameter. When flow again in-
creases above the preset point the N-300 resumes
operation.
To set the low flow shut off, figure 41, press and
release the Select key. The value entry will begin to
flash when selected. Use the Up Arrow key to increase
the value and the Down Arrow key to decrease the
value. When a new value has been chosen, press the
Enter key to store the new value into memory. The
entered value will stop flashing when it has been loaded
into the memory. Press the Down Arrow key to
advance to the next parameter.
The flow (no signal) input setting, is the predeter-
mined percentage of max gas flow that the operator
would like the controller to default to in the event that the
actual flow input signal is lost.
Note: the Flow (no signal) input functions will only be
active with analog input signals 1-5 VDC and 4-20 mA.
To set the flow (no signal) input, figure 42, press and
release the Select key. The value entry will begin to
flash when selected. Use the Up Arrow key to increase
Or
pmp bat vmtr sig tnk
Maximum Gas Flow
5 0 G al/min
pmp bat vmtr sig tnk
Maximum Gas Flow
15.00 liters/min
Select
Enter
pmp bat vmtr sig tnk
Low Flow Shutoff
2.0% Max LPG Flow
Select
Enter
Figure 40
Figure 41
pmp bat vmtr sig tnk
Flow (No Signal)
20.0% Max Gas Flow
Select
Enter
Figure 42