YZ Systems, Inc. • 3101 Pollok Drive • Conroe, Texas • USA • 77303 • P: 936.788.5593 • F: 936.788.5720
Page 114
NJEX 7300L ver.09042003
ReturnTo:
F: 1.936.788.5720,
NJEX-7300L (serial number/N-300 version x.xx/mfg. date):
Date:
Your Name:
L
OCATION
:
Site ID:
Attending Technicicans:
Telephone:
C
ONDITIONS
:
Pipeline Pressure:
Expansion Tank (25 psi) (1.72 Bar):
Bulk Tank (30-35 psi) (2.07-2.41 Bar):
cc/stroke:
Supply Actuation (75 psi) (5.17 Bar):
Pump Actuation (See Flow Chart for pressure):
meter level:
Gas Flow Rate (Gal./Min.) (Liter/Min.):
Bulk Odorant Storage Level:
flow input:
Ambient Temp Range:
Date of Last Problem (mm/yr):
battery VDC:
P
ARAMETERS
:
Injection Rate:
R
UN
M
ODE
:
Pump Displacement:
Proportional-To-Time
Proportional-To-Flow
Odorant Density:
Analog
Max Gas Flow:
Linear
Low Flow Shutoff:
Non-linear
Flow (no signal):
Pulses
Max Time/Stroke:
PPS
Odorant Output:
A
LARMS
:
P u m p
Verometer
Signal
Overpumping
Slow Fill
Odorant Inlet Cable
Low Flow
Underpumping
No Fill
Odorant Inlet Low
Over Flow
Pump Failure
Vmtr-Cable
Odorant Inlet High
Loss of Signal
FLValve-Fail
XTank Cable
Tank
Leakage
XTank Low
Battery
Low Level
XTank High
Low Battery
High Level
P
UMP
P
ROBLEMS
O
NLY
:
The correct hydraulic fluid level should be even with the “Oil Level Indication” located aproximatelty1/2 way down in
the oil reservoir.
C
HECK
O
NE
:
level is fine and moves up and down with each stroke
level is low but still moves fine
level does not move
NJEX TROUBLE SHOOTING FORM