1
Actual reserve time is dependant on age and condition of battery and the usage rate of the NJEX System.
Operation Specifications
Maximum Odorant Output:
19.8 gallons/day
(67 liters/day)
Maximum Operating Pressure:
1,440 psig
(99.28 Bar (g)
Operating Temp Range:
0 to 140 degrees F.
(17°C to 60°C)
Power Supply:
LPS-120/240 volt-
50/60Hz AC charger,
Battery Reserve
1
:
Approximately 30 days
Gas Flow Rate Input Signal:
1-5 VDC, 4-20 mA or pulse
Note: at temperatures below 32º F (0º C), condition-
ing of the actuation gas supply may be required.
Where the actuation gas supply has a high water
content and/or a low hydrocarbon dew point, addi-
tional actuation gas filtration or heating of the actua-
tion gas supply may be necessary. Bottled nitrogen
can also be used during cold operating conditions to
avoid condensation in the actuation gas supply line.
In addition, operation at extreme temperatures will
affect seal and diaphragm performance. To prolong
the service of seals and diaphragm, adequate heat
should be provided to maintain an operating environ-
ment above 30° F (-1º C).