YZ Systems, Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: 936.788.5593 F: 936.788.5720
Page 7
DP-2010 TP ver.10012004
S
ECTION
2: S
YSTEM
I
NSTALLATION
Standard Mounting Location
1 The customer supplied sample probe should
be a minimum of five pipe diameters from any
device which could cause aerosols or significant
pressure drops.
2 The sample probe should not be located
within the defined meter tube region (AGA 3
manual).
A = The number of unobstructed, straight pipe
diameters upstream (see AGA - 3 manual).
B = The number of unobstructed, straight pipe
diameters downstream (see AGA - 3 manual).
0HWHU7XEH
2SWLPXP6DPSOHU3UREH/RFDWLRQV
'LIIHUHQWLDO3UHVVXUH'HYLFH
)ORZ
$
%
figure 3