Wegj Install - Mar2007

Page 2 of 4

WEGJ – TYPICAL FLUE INSTALLATION 

(drawings on the following pages are not to scale)

FIG A

FIG B

5mm Max

300

570

100

50

LINER POSITIONED BY SPIDER

BRACKETS. TOP/BOTTOM

FLUE

TOP CAP (Fits inside flue)

FLASHING

25 MM BETWEEN LINER

AND ANY TIMBER.

TIMBER RAILS

SUPPORT ANGLES

25 mm min BETWEEN LINER

& ANY TIMBER

LINER POSITIONED BY SPIDER

BRACKETS TOP & BOTTOM.

SUPPORT ANGLES

300mm sq TIMBER FRAME

CEILING

1200mm LINED

BACK GUARD

  TERTIARY

BACK GUARD

TWO SEISMIC RESTRAINT

attachment points.

cover with caps.

60

0m

m

 A

B

O

V

E

 T

H

E

 R

ID

G

E

 L

IN

E

 (M

IN

) *

If 

w

ith

in

 3

.0

m

 o

f r

id

ge

 li

ne

*

1200mm FRONT GUARD

4.

M

. M

IN

IM

U

M

Note: All Dimensions are in millimetres.

ASH FLOOR

PROTECTOR

Top Front 

 Angled 

Deflector

CONDITIONS FOR FLUES 

(Refer Fig. E)

1.  The FLUE shall extend to:

Not less than 600mm above the highest point on the

roof if within 3.0m of that point.

Not less than 1000mm above the intersection

point with the roof and not lower than any point

of the roof within 3.0m.

In any case the length of the flue shall not be

less than 4.6m from the ash floor protector.

In some situations the Local Council may vary

the above requirements.

2.  All parts of the chimney exposed to the outside

air shall be suitably insulated in accordance with

the manufacturers' recommendations.

When loose- fill insulation is used in the

adjacent ceiling space, maintain clearance

between the secondary shield and the loose-fill

insulation by provision of a boundary extending

200mm above the ceiling top surface.

This non-combustible boundary shield shall be

capable of preventing accidental migration of

the loose-fill by any action of wind or by

persons moving in the ceiling space.

CEILING PLATE

25mm min. BETWEEN LINER & ANY TIMBER

ENLARGEMENT OF CEILING ASSEMBLY

300

300mm Sq. TIMBER FRAME

TIMBER RAILS

SUPPORT ANGLES

LINER POSITIONED BY SPIDER

BRACKETS. TOP/BOTTOM

LOOSE FILL BOUNDARY

SECONDARY SHEILD.

CUT CEILING MATERIAL

BACK 25mm CLEAR

OF BOUNDARY SHEILD.

CEILING

25