Yoshitake SU-20H Скачать руководство пользователя страница 1

PDT

169a

 

 

MODEL

 

SU-20H 

 

STRAINER 

 

Installation & Operation Manual 

 

We thank you very much for using the Yoshitake Products. In order to put in use our product 

correctly and safely, please make sure to read this manual thoroughly prior to the installation. 
Also we kindly request you to keep this manual with care at your hand. 

 

 

The following safety symbols are used in this manual. 

 

 

 

 

Warning 

Indicates that mishandling this product might cause fatal or 

serious bodily injury. 

 

 

Caution 

Indicates that mishandling this product might cause bodily 

injury or material damage. 

 

Contents 

Overview ····························································· 1 
1.

 

Features ·························································· 1 

2.

 

Specifications ···················································· 1 

3.

 

Dimensions and Weights ······································· 1 

4.

 

Operation ························································· 2 

5.

 

Pressure loss 

5.1.

 

Selection of pipe diameter ·································· 3 

5.2.

 

Pressure loss diagram ······································· 3 

6.

 

Installation 

6.1.

 

Example of piping ··········································· 4 

6.2.

 

Precautions during installation and inspection ········· 4 

7.

 

Operating Procedure 

7.1.

 

Precautions during operation and inspection ··········· 5 

8.

 

Maintenance Procedure 

8.1.

 

Troubleshooting ·············································· 5 

8.2.

 

Precautions during maintenance and inspection ······· 5 

8.3.

 

Disassembly Procedure ····································· 6 

8.4.

 

Assembly Procedure ········································· 6 

8.5.

 

Precautions 

during 

change the screen ···················· 6 

8.6.

 

Exploded drawing············································ 7 

After Sale Service 

 

 
 
 

Содержание SU-20H

Страница 1: ...Caution Indicates that mishandling this product might cause bodily injury or material damage Contents Overview 1 1 Features 1 2 Specifications 1 3 Dimensions and Weights 1 4 Operation 2 5 Pressure los...

Страница 2: ...KFF flanges JIS 20KRF flanges BS4504 PN16 flanges Maximum Pressure 1 0 MPa 2 0 MPa 1 6 MPa Temperature range 5 80 Material Body Ductile Cast Iron Screen Stainless Steel Standard Screen Perforated plat...

Страница 3: ...Parts Name The screen removes dust scale and other foreign matter out of the fluid flown from inlet port of strainer Figure 2 1 Body 8 Plug 2 Cover 9 O Ring 3 Screen 10 Bolt 4 Bolt 11 Eyebolt 5 Lock N...

Страница 4: ...ation due to turbulent flow If the pipe diameter is too large not only the piping cost but also the heat loss will be increased As one method of selection of suitable pipe diameter Japan Industrial St...

Страница 5: ...let port of the product respectively If installed in opposite direction it will not function as designed 2 Carry out the securing of pipes and the product properly Excessive piping stress may cause th...

Страница 6: ...e and clean the screen 2 Pressure gauge is damaged 2 Renew the Pressure gauge 8 2 Precautions during maintenance and inspection Warning 1 Completely discharge internal pressure from the strainer lines...

Страница 7: ...hten the bolts evenly on each bolt in turn of diagonal position The fluid may leak from strainer If the fluid is of high temperature the leakage may cause being scalded 4 Cleaning down the sealing sur...

Страница 8: ...7 EPDT 169a 8 6 Exploded drawing Part names shown in boxes are consumable items Figure 7 Exploded drawing...

Страница 9: ...improvement without any prior notice After the discontinuation of the product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage d...

Отзывы: