Yoshitake GD-24GS Скачать руководство пользователя страница 1

EPDT-175d

 

 

This symbol indicates a potentially hazardous situation that, if not avoided, 
could result in death or serious injury. 

This symbol indicates a hazardous situation that, if not avoided, may result 
in minor or moderate injury. (“Caution” may also be used to indicate other 
unsafe practices or risks of property damage.) 

Model GD-24GS

 

 

Pressure Reducing Valve 

 

Installation & Operation Manual 

 

Please read this manual thoroughly before using the pressure reducing valve, so that 
you may do so correctly and safely. 
Please carefully store this manual in a handy place. 

 

- --- -

The following safety symbols are used in this manual. 

-- -- -

 

 
 

Warning

 

 

 

 

Caution

 

 
 
 

Contents 

 

1. Specifications ································································ 1 
2. Dimensions and Construction 

2.1  Dimensions and Weight ················································· 2~3 
2.2  Construction ·································································· 4 

3. Operation ··········································································· 4 
4. Nominal Size Selection 

4.1  Nominal Size Selection Chart ············································ 5 
4.2  Flow Rate Characteristics Chart ········································ 6 
4.3  Pressure Characteristics Chart ·········································· 6 

5. Installation 

5.1  Piping Example ······························································ 7 
5.2  Warning and precaution on installation ························ 7~8 

6. Operating Procedure 

6.1  Warning and precaution on operation ································· 8 
6.2  Adjustment Procedure ···················································· 8 

7. Maintenance Procedure ························································· 9 

7.1  Warning and precaution on maintenance and inspection ···· 9 
7.2  Troubleshooting ···························································· 10 

8. Exploded Drawing ······························································ 10 
After Sales Service 

 
 
 
 
 

Содержание GD-24GS

Страница 1: ...y Please carefully store this manual in a handy place The following safety symbols are used in this manual Warning Caution Contents 1 Specifications 1 2 Dimensions and Construction 2 1 Dimensions and...

Страница 2: ...water Inlet pressure 0 2 1 6MPa Reduced pressure 0 05 0 55MPa Min differential pressure 0 05MPa Max pressure reducing ratio 10 1 Temperature 5 80 Material Body Bronze Valve Disc Urethane rubber Valve...

Страница 3: ...20A Rc 3 4 169 216 51 2 8 25A Rc 1 193 243 63 3 9 32A Rc 1 1 4 236 285 80 5 7 40A Rc 1 1 2 286 343 90 9 7 50A Rc 2 343 404 112 17 5 GD 24 mm Nominal size d L H H1 Weight kg 15A Rc 1 2 80 193 41 5 1 8...

Страница 4: ...ize d d1 L H1 Screen Weight kg ds ls 15A Rc 1 2 R 1 2 80 46 18 32 0 25 20A Rc 3 4 R 3 4 90 51 20 35 0 35 25A Rc 1 R 1 105 63 25 50 0 55 32A Rc 1 1 4 R 1 1 4 130 80 32 60 1 00 40A Rc 1 1 2 R 1 1 2 150...

Страница 5: ...installed at the time of shipment and replace it with the included pressure gauge Corrosion resistance is not considered because the plug is for airtightness test at the time of shipment 3 Operation R...

Страница 6: ...2 m s flow velocity within the pipe is ideal Cv Value Nominal size 15A 20A 25A 32A 40A 50A Cv value 1 5 1 9 3 4 7 10 Calculation formula for Cv value P G V Cv 365 0 P1 Inlet pressure MPa A V Rated fl...

Страница 7: ...6 EPDT 175d 4 2 Flow Rate Characteristics Chart 4 3 Pressure Characteristics Chart...

Страница 8: ...service life 7 When pressure reducing in two stages secure at least 3 m between the valves Failure to do so may result in malfunction affecting the original performance 8 Install the valve in proper...

Страница 9: ...d down stream of pressure reducing valve Water scales developed in the piping may cause erratic operation of pressure reducing valve 6 2 Adjustment Procedure GD 24 pressure reducing valve is set at 0...

Страница 10: ...tion Failure to do so may result in injury or burns due to residual pressure or spillage around the valve Caution 1 To maintain the functions and performance of pressure reducing valve perform periodi...

Страница 11: ...eign mater If scratches exist replace it Pressure does not rise to the desired level 1 Screen 22 is clogged 2 Pressure gauge 19 malfunction 1 Disassemble and clean 2 Replace the pressure gauge 19 Leak...