Yoshitake CF-60 Скачать руководство пользователя страница 1

EPDT-336a

 

MODEL CF-60 

Constant Flow Valve 

 

PRODUCT MANUAL

 

.

 

Thank you very much for choosing the Yoshitake’s product. To ensure the correct and safe use of the product, 

please read this manual before use. This manual shall be kept with care for future references. 

The symbols used in this manual have the following meanings. 

 

          Warning 

This  symbol  indicates  a  potentially  hazardous  situation  that,  if  not  avoided, 
could result in death or serious injury. 

          Caution 

This symbol indicates a hazardous situation that, if not avoided, may result in 
minor or moderate injury or may result in only property damage. 

 

 

Table of Contents 

 

1. Specifications ························································· 1~2 

2. Structure, Dimensions and Weight ······························ 3~4 

3. Performance characteristic chart 

3.1 Noise characteristic chart ······································· 5 

3.2 Flow rate characteristic chart ·································· 5 

4. Precautions for installation ··········································· 6 

5. Precautions for operation ············································· 7 

6. Maintenance 

6.1 Troubleshooting ··················································· 8 

6.2 Precautions for maintenance and inspection ·············· 8 

Warranty Information 

 

 

 

 

 

 

 

 

 
 
 
 
 
 

 

 
 

 

Содержание CF-60

Страница 1: ...situation that if not avoided could result in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in o...

Страница 2: ...tion JIS Rc screwed Flangeless wafer type See below table Connectable flange standard table Installation posture Horizontal or vertical installation The product conforms to the standard of the Japanes...

Страница 3: ...min Yellow 115L min Black 150L min Red 210L min Light Blue 270L min Blue w Hole 65A Wafer type 100L min Green 125L min White 150L min Yellow 190L min Black 250L min Red 350L min Light Blue 450L min B...

Страница 4: ...g 25A Rc 1 57 41 0 4 32A Rc 1 1 4 61 50 0 6 40A Rc 1 1 2 63 58 69 1 0 50A Rc 2 77 70 74 1 4 Fig 1 Structure Dimensions and Weight No Parts name 1 Body 2 Cartridge 3 C type retaining rings internal 4 L...

Страница 5: ...DT 336a Wafer type Fig 2 Structure Dimensions and Weight No Parts name 1 Body 2 Cover 3 Cartridge 4 Low head screw mm Nominal size L A B Weight kg 65A 13 147 115 1 0 80A 13 158 126 1 2 100A 13 178 146...

Страница 6: ...ise characteristic chart 3 2 Flow rate characteristic chart Fig 3 2 Flow rate characteristic chart Noise Differential pressure Differential pressure Flow rate The chart shows the noise level at the ma...

Страница 7: ...the bundled parts 6 If component having negative effect on inner parts is included in fluid and environment deterioration of rubber parts is accelerated and causes outside leakage and functional disor...

Страница 8: ...foreign substances such as scale material leads to prevent the product from functioning properly 3 If case of a possible frozen line take proper measures to remove water inside the piping or equip the...

Страница 9: ...burns Trouble Cause Remedy No flow or Poor flow The cartridge is clogged Clean the cartridge The cartridge is broken Replace the product The set flow rate is wrong Confirm the flow rate with the indi...

Отзывы: