YO Analog
User guide
v2.0
page 6/15
Device configuration
Configurable parameters
A few parameters must be set in order to send data to the gateway. The default firmware is
configured in ABP connection type with predefined
deveui
,
appkeyota
,
keyotaa
,
nwkskey
by MCU.
CONFIGURABLE PARAMETERS
NAME
DESCRIPTION
POSSIBLE
VALUES
DEFAULT
VALUE
READ/
WRITE
devname
Device name
LNAN
LNAN
R
conntype
Connection type
0 – OTAA
1 – ABP
1
R/W
deveui
Device address EUI
8 B (HEX)
predefined
R/W
appkeyota OTAA application EUI
8 B (HEX)
predefined
R/W
keyotaa
OTAA key
16 B (HEX)
predefined
R/W
addrabp
ABP device address
4 B (HEX)
predefined
R/W
nwkskey
Network Session Key
16 B (HEX)
predefined
R/W
appskey
Application Session Key
16 B (HEX)
predefined
R/W
advble
Interval advertising Bluetooth [s]
MS_INPUT
1
1600
R/W
measinter Measuring and/or sending interval
LoRa [s]
1–999999
300
R/W
measlevel
Measuring threshold [%]
2
1–9999
20
R/W
input1
Analog input type 1
1 – 4–20 [mA]
2 – 0–10 [V]
1
R/W
input2
Analog input type 2
1
R/W
input3
Analog input type 3
1
R/W
input4
Analog input type 4
1
R/W
input5
Analog input type 5
1
R/W
input6
Analog input type 6
1
R/W
1
Calculation formula: MS_INPUT = INTERVAL_MS × 1.6.
2
Sets the threshold that is used to save the peak timestamp and value that is between regular.
REV 2.0.0