246809-YTG-E-0507
Unitary Products Group
23
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
YMB03011
INDOOR COIL MODEL NO.
AHP30
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
800
1000
1200
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
36.0
2.2
4.2
36.8
2.1
4.4
37.7
2.0
4.6
70
35.2
2.5
3.8
36.2
2.3
4.0
37.2
2.2
4.2
80
34.5
2.7
3.4
35.6
2.5
3.6
36.6
2.4
3.8
47
60
29.9
2.1
3.7
30.9
2.0
3.9
32.0
1.9
4.1
70
29.6
2.3
3.4
30.6
2.2
3.5
31.5
2.1
3.7
80
29.4
2.5
3.1
30.2
2.4
3.2
31.0
2.3
3.4
40
60
27.7
2.0
3.5
28.5
1.9
3.7
29.3
1.8
3.8
70
27.2
2.2
3.2
28.0
2.1
3.3
28.8
2.0
3.4
80
26.8
2.4
2.9
27.5
2.3
3.0
28.2
2.2
3.1
30
60
21.5
1.9
2.9
23.2
1.8
3.1
24.8
1.8
3.3
70
22.3
2.1
2.7
23.3
2.0
2.8
24.2
1.9
3.0
80
23.2
2.4
2.6
23.4
2.2
2.6
23.6
2.1
2.7
17
60
18.8
1.7
2.8
18.9
1.8
2.6
19.1
1.8
2.5
70
18.4
2.0
2.4
18.6
2.0
2.4
18.8
1.9
2.3
80
18.0
2.3
2.1
18.3
2.1
2.1
18.6
2.0
2.2
10
60
16.6
1.8
2.4
16.8
1.7
2.4
17.1
1.7
2.4
70
16.1
2.0
2.1
16.5
1.9
2.1
16.8
1.8
2.2
80
15.7
2.2
1.8
16.1
2.1
1.9
16.5
2.0
2.0
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
MA12B
FC/MC35B
1.00
1.00
1.00
MA12B
FC/MC42B
1.00
1.00
1.00
MV12B
FC/MC35B
0.98
1.05
0.93
MV12B
FC/MC42B
0.98
1.05
0.93
AV36
–
0.98
1.05
0.93
F*FP040
–
1.00
1.00
1.00
–
FC/MC/PC35
1.00
1.00
1.00
–
HC36
1.00
1.00
1.00
–
HD36
1.00
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
PV8*B16
FC/MC/PC35B
0.98
1.05
0.93
P(C,V)9*B12
FC/MC/PC35B
0.98
1.06
0.93
PV8*B16
HC36
0.99
1.03
0.96
P(C,V)9*B12
HC36
0.99
1.03
0.96
PV8*A12
HD36
0.99
1.03
0.96
PV8*B16
HD36
0.98
1.05
0.93
PV8*C16
HD36
0.98
1.06
0.93
PV8*C20
HD36
0.98
1.06
0.93
PV9*A12
HD36
0.99
1.03
0.96
P(C,V)9*B12
HD36
0.99
1.03
0.96
P(C,V)9*C16
HD36
0.99
1.05
0.94
P(C,V)9*C20
HD36
0.99
1.05
0.94