JOHNSON CONTROLS
48
FORM 155.35-ICOM2.EN.CE/GB (1018)
DATE: 10/30/2018
SECTION 4 - TECHNICAL DATA
Communication Data
TABLE 8 -
READ COMMAND
ITEM
DISPLAY
UNIT
ADDRESS
CONTENT
SET
V
ALUE
1
Set Point (Chilled / Hot water outlet
temp.)
7.0
°C
00001
0050~1000 unit, 1 unit=0.1 °C
2
Automatic stop temp. at cooling
mode (thermo-off temp)
5.0
°C
00003
0040~1000 unit, 1 unit=0.1 °C
3
Temp. difference of Automatic start
and stop control at cooling mode
5.0
°C
00005
0001~1000 unit, 1 unit=0.1 °C
4
Automatic stop temp. at heating
mode (thermo-off temp)
62.0
°C
00007
0040~1000 unit, 1 unit=0.1 °C
5
Temp. difference of Automatic start
and stop control at heating mode
5.0
°C
00009
0001~1000 unit, 1 unit=0.1 °C
OPERA
TION CONDITION
6
Operation condition
0 or 1
or 2
-
00021
0:STOP, 1:COOLING OPERATION,
2:HEATING OPERATION
7
Local or Remote mode condition
0 or 1
-
01001
0:LOCAL, 1:REMOTE
8
Solution pump condition
0 or 1
-
01003
0:STOP,1:OPERATION
9
Refrigerant pump condition
0 or 1
-
01005
0:STOP,1:OPERATION
10
Load limit condition
0 or 1
-
01009
0:NORMAL OPERATION
1:LOAD LIMIT OPERATION
11
Control manipulated variable.
100
%
00023
-0100~1100 unit, 1 unit=0.1%
12
Failure signal.
0 or 1
-
01011
0:NORMAL OPERATION
1:FAILURE OCCUR
13
Alarm signal
0 or 1
-
01013
0:NORMAL OPERATION
1:ALARM OCCUR
MEASUREMENT
V
ALUE
15
Chilled / Hot water inlet temp.
12.0
°C
00083
0001~4000 unit, 1 unit=0.1 °C
16
Chilled / Hot water outlet temp.
7.0
°C
00085
0001~4000 unit, 1 unit=0.1 °C
17
Refrigerant temp. at evaporator
5.0
°C
00087
0001~4000 unit, 1 unit=0.1 °C
18
Cooling water inlet temp.
32.0
°C
00089
0001~4000 unit, 1 unit=0.1 °C
19
Cooling water outlet temp
37.0
°C
00091
0001~4000 unit, 1 unit=0.1 °C
20
Absorber solution temp.
38.0
°C
00093
0001~4000 unit, 1 unit=0.1 °C
21
High temperature generator
solution temp.
145.0
°C
00095
0001~4000 unit, 1 unit=0.1 °C
22
Exhaust gas temp.
220.0
°C
00097
0001~4000 unit, 1 unit=0.1 °C
23
High temperature generator
pressure
61.0
kPa
00099
0001~1100 unit, 1 unit=1 kPa
24
Motor opening rate
100
%
00101
0001~1100 unit, 1 unit=0.1%
25
High temperature generator
concentration
63
%
00103
0001~1100 unit, 1 unit=0.1%
26
Purge tank pressure
2.0
kPa
00105
0001~4000 unit, 1 unit=0.1 kPa
Содержание YHAU-CE
Страница 10: ...JOHNSON CONTROLS 10 FORM 155 35 ICOM2 EN CE GB 1018 DATE 10 30 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 14: ...JOHNSON CONTROLS 14 FORM 155 35 ICOM2 EN CE GB 1018 DATE 10 30 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 84: ...JOHNSON CONTROLS 84 FORM 155 35 ICOM2 EN CE GB 1018 DATE 10 30 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 126: ...JOHNSON CONTROLS 126 FORM 155 35 ICOM2 EN CE GB 1018 DATE 10 30 2018 THIS PAGE INTENTIONALLY LEFT BLANK...