background image

LX SERIES

DUCTLESS MULTI-ZONE SPLIT
HEAT PUMPS

16 SEER – 1 PHASE

1.5 THRU 3.5 NOMINAL TONS

MODELS: 
INDOOR-DHPM/OUTDDOR-DHMF

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at 

www.upgnet.com

Additional rating information can be found at 

www.ahridirectory.org

WARRANTY SUMMARY*

Standard 2-Years limited parts warranty.
Standard 6-Years limited compressor warranty.

 

TECHNICAL
GUIDE 

TECHNICAL
GUIDE 

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

923212-UTG-A-0113

DESCRIPTION

The Multi Zone Series are ductless climate systems. They are designed
with a matching indoor unit for optimum performance and efficiency.
These climate systems are supported with accessories and documents
to serve specific functions.

FEATURES

Variable Frequency Rotary Compressor - 

Twin rotary inverter compressor

on all models features high efficiency operation that modulates down to 15
Hz and as high as 120 Hz for reduced vibration and quiet operation. Brush-
less DC motor uses powerful Neodymium magnets that are approximately
15-20 times stronger than ferrite magnets used in conventional AC compres-
sors. The DC Inverter Control provides continuous operation, while adjusting
capacity according to room temperature. The accurate sensing of cooling or
heating loads prevents frequent changes in capacity and ensures efficient,
economical operation.

Low Ambient Cooling Operation Down to 5 °F - 

This feature allows for a

space to be air-conditioned even in outdoor temperatures as low as 5 °F.
This cooling ability is important when dealing with server equipment rooms,
surveillance mechanical rooms, restaurant kitchens, fitness centers, and
more.

Condenser High Temperature Protection - 

The outdoor coil thermistor

continuously monitors the temperature and communicates with the micro-
processor. Depending on the temperature measured, the compressor will be
allowed to increase the frequency if needed to meet the load or is forced to
run at the current or reduced frequency. If the temperature gets excessively
high the compressor will be de-energized. 

High Pressure Discharge Temperature - 

The compressor discharge line

thermistor continuously monitors the temperature and communicates with
the microprocessor. Depending on the temperature measured, the compres-
sor will be allowed to increase the frequency to meet the load or is forced to
run at the current or reduced frequency. If the temperature gets excessively
high, the compressor will be de-energized. 

Defrost Control (Heat Pump Models) - 

Defrost cycle is automatically

enabled if there is a build-up of frost on the outdoor coil. Outdoor fan and
indoor blower operation is terminated during the defrost cycle. H1 is dis-
played on the indoor unit panel on the front cover during a defrost cycle.
Reversing Valve (Heat Pump Models) - 4-way interchange reversing valve
effects a rapid change in direction of refrigerant flow resulting in quick
changeover from cooling to heating and vice versa. Valve operates on sys-
tem pressure differential between outdoor unit and indoor unit.
R-410A Refrigerant - Unit is pre-charged with R410A refrigerant that uses
PVE refrigerant oil. Polyvinylether (PVE) is an innovative refrigerant oil spe-
cially formulated for hydrofluorocarbon (HFC) refrigeration systems. In addi-
tion to providing lubricating properties, it also has a number of other applied
advantages that help to increase the reliability of the refrigeration systems
where it is applied.

Refrigerant Line Connections, Service Valve - 

Outdoor units are

designed with easy service and maintenance in mind. Maintenance points
are located behind easy-access panels, to make installation and service a
breeze for a trained technician. Flare connection lines are located on side of
unit cabinet. Fully serviceable brass service valve prevents corrosion and
provide access to refrigerant system. Shut-off valve that can be fully shut off
while 2-way service valve (with service port) may be front seated to manage
refrigerant charge while servicing system. 

Air Deflection Louvers - 

Horizontal louvers default to the cooling or heating

position when the unit is operating. Horizontal louvers can be set to a preset
oscillating range or fixed position from the wireless remote control. Full oscil-
lating is the default setting when button is pushed. Vertical louvers can be
manually adjusted to direct the airflow for optimal comfort.
Indoor Coil Freeze Protection - The indoor coil thermistor monitors the coil
temperature continuously. Any time the coil temperature drops below 30°F,
the compressor and the outdoor fan (30 seconds later) will be switched off
until the coil temperature rises above 43°F and the compressor has been off
for a minimum of 3 minutes.

I FEEL Function - 

When I FEEL is activated, the system will satisfy your

cooling or heating temperature setpoint where the remote control is located.
When I FEEL is deactivated, the system will satisfy the cooling or heating
temperature setpoint where the indoor unit is located. This feature provides
homeowners with optimum comfort whether they are near or far from the
indoor unit. 

Hot Heat Pump (cold air prevention) -

 In heating mode, the indoor fan will

be delayed from 1 to 3 minutes to allow refrigerant to warm up and avoid
cold blow. This may occur during: 

• Initial start-up of a heating cycle 
• Immediately after completion of an Auto mode operation 

Heating under extremely low indoor temperatures

Содержание DHPM09NWM42Q1

Страница 1: ...he outdoor coil Outdoor fan and indoor blower operation is terminated during the defrost cycle H1 is dis played on the indoor unit panel on the front cover during a defrost cycle Reversing Valve Heat...

Страница 2: ...acity 09 3 4 Ton 12 1 Ton 18 1 5 Ton 24 2 Ton 30 2 5 Ton 36 3 Ton 42 3 5 Ton System Type NW Indoor Wall Mount Unit CS Outdoor Unit with Single Indoor Unit CM Outdoor Unit with Multiple Indoor Units St...

Страница 3: ...tput of Fan Motor w 20 20 20 Fan Motor Capacitor uF 1 1 1 5 Fan Motor RLA A 0 2 0 2 0 28 Fan Type Piece Cross flow 1 Cross flow 1 Cross flow 1 Diameter Length inch 3 6 x 25 4 3 6 x 25 4 3 9 x 28 0 Dia...

Страница 4: ...Type Piece Axial flow 1 Axial flow 1 Axial flow 1 Axial flow 1 Fan Diameter inch 17 5 20 5 20 5 20 5 Defrosting Method Automatic Defrosting Automatic Defrosting Automatic Defrosting Automatic Defrost...

Страница 5: ...or Speed rps 0 20 40 60 80 100 0 2 4 6 8 10 12 Cooling 12 10 8 6 4 2 0 0 0 2 0 4 0 6 0 8 0 0 1 Compressor Speed rps Current A Heating 24K 30K 9K 9K 9K Heating Cooling 12 10 8 6 4 2 0 0 2 0 4 0 6 0 8 0...

Страница 6: ...d rps Current A Cooling Heating 18K 9K 9K Capacity Ratio Outdoor Temp F 5 20 40 45 50 60 70 80 90 100 110 120 50 40 40 50 Heating Cooling 120 110 100 90 80 70 60 110 105 100 95 90 Outdoor Temp F Capac...

Страница 7: ...e Standard Pressure Heat Exchanger Pipe Temperature Indoor Fan Mode Outdoor Fan Mode Compressor Frequency Hz Indoor Outdoor P MPa T1 F T2 F COOLING 80 66 9 95 75 18K 9K 9K 0 9 to 1 1 50 to 55 150 to 1...

Страница 8: ...Products OUTDOOR UNITS 18K 24K 30K Unit Outdoor side noise 18K 9K 9K 24K 30K 9K 9K 9K 60 6 50 40 40 30 20 0 0 2 Compressor Frequency Hz Compressor Frequency Hz Noise level dB A 42K Unit 80 100 70 65...

Страница 9: ...56 2 2 56 2 51 4 101 5 127 2 51 10 9 277 Indoor Unit Dimensions Model Size A B C Unit Gross Weight Heat Pump 09K 12K 33 838 7 178 10 9 277 37 lbs 17 kg 18K 37 940 8 203 12 305 46 lbs 21 kg B A C Outdo...

Страница 10: ...mbol Color Symbol Symbol Part Name INDOOR UNIT BU BlUE BN BROWN PROTECTIVE EARTH YE YELLOW GN GREEN RD RED BK BLACK YEGN YELLOW GREEN OUTDOOR UNIT Symbol Part Name Symbol Color Symbol Symbol Color Sym...

Страница 11: ...Johnson Controls Unitary Products 11 923212 UTG A 0113 Electrical Wiring 18K Outdoor Heat Pumps 24K Outdoor Heat Pumps...

Страница 12: ...923212 UTG A 0113 12 Johnson Controls Unitary Products 30K Outdoor Heat Pumps 42K Outdoor Heat Pumps...

Страница 13: ...y the start of the compressor The defrost timer is initiated and the frequency of the compressor increases to reach the defrost frequency 4 Oil returned in heating mode Oil return happens when the sys...

Страница 14: ...8 102 9 77 15 147 2 3 217 217 4 0 925 8 6 97 4 78 8 14 36 149 3 105 219 2 0 898 10 4 92 22 80 6 13 74 150 8 2 998 221 0 873 12 2 87 35 82 4 13 16 152 6 2 896 222 8 0 848 14 82 75 84 2 12 6 154 4 2 797...

Страница 15: ...95 13 04 165 2 3 04 235 4 0 93 26 6 76 24 96 8 12 51 167 2 94 237 2 0 904 28 4 72 41 98 6 12 168 8 2 844 239 0 88 30 2 68 79 100 4 11 52 170 6 2 752 240 8 0 856 32 65 37 102 2 11 06 172 4 2 663 242 6...

Страница 16: ...342 8 77 49 19 147 2 10 54 217 4 3 04 8 6 323 9 78 8 47 08 149 10 18 219 2 2 955 10 4 306 2 80 6 45 07 150 8 9 827 221 2 872 12 2 289 6 82 4 43 16 152 6 9 489 222 8 2 792 14 274 84 2 41 34 154 4 9 165...

Страница 17: ...after turning off all power supplies before disassembly STEPS PROCEDURES 1 Before disassembly of the unit 2 Remove filter 3 Remove display Axonometric drawing for the complete unit panel clasps filter...

Страница 18: ...c box STEPS PROCEDURES Clasp Panel Pull the clasps at both sides slightly and then remove the panel horizontal louver Remove the axial bush on the horizontal louver and then remove the horizontal louv...

Страница 19: ...w Cap Screw Front Case a Remove the screw caps on front case b Remove screws connecting the front case c Remove the front case screw Remove earthing screws and then remove the earthing wire Clasp Clas...

Страница 20: ...TEPS PROCEDURES temperature sensor Pull out the indoor temperature sensor Screw Electric Box a Pull out 6 sockets on PCB board b Pull out two screws on electric box c Remove the electric box Water Tra...

Страница 21: ...e for indoor unit and then remove the pipe stopping Screw Damping Board Remove 2 screws on damping board and then remove the damping board Screw Evaporator a Remove screws between evaporator and botto...

Страница 22: ...e and motor 19 Remove cushion rubber STEPS PROCEDURES Blade Motor a Remove screws fixing cross flow blade and motor b Remove the motor sub assy c Separate two cross flow blade Cushion Rubber a Remove...

Страница 23: ...ove the screws connecting the top panel and panel and side panels Remove the top panel Loosen the screws fixing the valve cover and then remove the valve cover Top Panel Valve Cover b Loosen the screw...

Страница 24: ...d grille and then remove the guard grille Guard Grille Twist off the screws fixing the handle and then remove the handle Handle Twist off the screws connecting the right side plate and chassis valve s...

Страница 25: ...the wiring terminal pull it upwards to remove the electric box Electric Box Electric Box 1 c Twist off the screws between electric box 1 and left side plate with screwdriver pull it upwards to remove...

Страница 26: ...ay Valve Unsolder the pipeline between compressor condenser gas and liquid valve and then remove the 4 way valve note release all refrigerant before unsoldering Gas Valve Liquid Valve Twist off the 2...

Страница 27: ...on compressor and then remove the compressor Isolation Sheet Twist off the screws connecting isolation sheet and end plate of condenser and chassis and then remove the isolation sheet Support Plate o...

Страница 28: ...IN6 ELBOW OUTSD 90DEG SPEEDICHANNEL 6 M10 S1 230 FB3 BEND FLAT 90 DEG SPEEDICHANNEL 3 M10 S1 230 FB4 BEND FLAT 90 DEG SPEEDICHANNEL 4 M10 S1 230 FB453 BEND FLAT 45 DEG SPEEDICHANNEL 3 M10 S1 230 FB454...

Страница 29: ...Johnson Controls Unitary Products 29 923212 UTG A 0113 NOTES...

Страница 30: ...bject to change without notice Published in U S A 923212 UTG A 0113 Copyright 2013 by Johnson Controls Inc All rights reserved Supersedes Nothing York International Corp 5005 York Drive Norman OK 7306...

Отзывы: