OWNER’S MANUAL

YDS04U-007aW

YORK INTELIGENT NETWORK AIR-CONDITIONING 
CENTRAL CONTROL MONITOR
AMR03M

Please read this installation manual carefully before installing your air conditioner.
Please keep this manual in a safe place for future reference.
This manual many be subject to change without notice for purpose of improvement.

Содержание AMR03M

Страница 1: ...CONDITIONING CENTRAL CONTROL MONITOR AMR03M Please read this installation manual carefully before installing your air conditioner Please keep this manual in a safe place for future reference This manu...

Страница 2: ...or units which together compose one LAN Local Area Network thus the CCM can central control to all air conditioners in the LAN including sending every kind of control order to every air conditioner an...

Страница 3: ...mal communication with NIM then Blank will be displayed in dynamic circulation Otherwise no any display f Lock Symbol means the CCM is in Lock state or the buttons are in Lock state ON means the butto...

Страница 4: ...n warning data of the air conditioner or the CCM The display range of ERROR code is E0 EF where E means ERROR 0 F means ERROR code or Network ERROR display 00 0F If no EEROR then display E and will be...

Страница 5: ...data of the first page will be displayed b The data of other pages can be displayed in circulation by pressing buttons or c The running state data of different air conditioners can be queried by press...

Страница 6: ...e air conditioner in network has malfunction or the CCM network itself has malfunction the indicator lamp will flash in 2Hz If one or more online air conditioners in network are in running state inclu...

Страница 7: ...ffect operation by remote controller If both are closed at the same time Urgent Stop switch takes priority 5 3 ON OFF Operation At any time all online air conditioners in CCM network will be carried o...

Страница 8: ...DE button to enter into MODE set and select circularly between COOLING HEATING and FAN ONLY Pressing OK button to confirm all settings and send to the corresponding air conditioners Press MODE button...

Страница 9: ...OFF MODE SET state In communication with PC NO 60 indoor unit in network is in Heating mode Set Temp 28 C Middle Fan Speed 4 5 hours Timer On 12 hours Timer Off ON and ERROR In communication with PC...

Страница 10: ...all online air conditioners will be off If all present online air conditioners are in OFF state then it will send ON order as follows if pressing at Mode Setting Page then it will carry out ON operat...

Страница 11: ...dule Protection PB Reserve EA Compressor Over current 4 times PA Reserve E9 Communication malfunction between PCB and Display board P9 Reserve E8 Fan motor checking out of control P8 Compressor Over c...

Страница 12: ...e or returned to the manufacturer for disposal Under No circumstances should refrigerant be vented to atmosphere Where appropriate drain the refrigerant oil from each system into a suitable container...