background image

4. Connection

5. Range

3

Installation of the tubular motor should be performed by specialists with 1kV or higher SEP-certified electrician's licence

(SEP - Association of Polish Electrical Engineers) or equal license. Device is designed to operate in places shielded from 

unfavourable weather conditions. Motor should be installed in accordance with all provisions of regional law and profes-

sional standards. All cables connecting power receiver with electric source should be protected from overload and 

short-circuits effects with devices automatically disconnecting power. Device should be powered with a separate source 

and protected only with a fast-blow fuse (never slow-blow fuse). Creating electrical system using inadequate fuse may 

result in loosing rights under the provisions of warranty. When connecting device to power source with cables with 

adequate cross-section should be used. Long-lasting output load capacity table should be the ground for choosing 

adequate cables.

Radio receiver range is a variable value and can differ from declared values depending on conditions in which device 

operates. Possible sources of changes in range are building construction, interference caused by other radio transmitters 

etc.

230 V / 50 Hz

200 m

35 m

433,92 MHz

L1

outdoor

L2

indoor

Operating

frequency

20

Roller shutter with remotely controlled motor

L2

L1

230 V AC

phase wire

neutral wire

protective wire

L

N

brown wire - phase

Mounting power supply wire,

antenna and microswitch.

230 V / 50 Hz

yellow-green wire - protective
blue wire - neutral

Содержание Smart Home 45 EM/S Series

Страница 1: ...tacle detection Non compliance with the speci cation might cause risk for life or health and can determine proper work of the blind We strongly recommend to comply with the speci cation Installation o...

Страница 2: ...used when placing motor in the tube During the adapter montage special attention must be paid not to damage the motor Motor and its control system should be kept out of children reach 2 PROGRAMMING B...

Страница 3: ...slow blow fuse Creating electrical system using inadequate fuse may result in loosing rights under the provisions of warranty When connecting device to power source with cables with adequate cross sec...

Страница 4: ...ING OF LIMIT POSITIONS USING A REMOTE CONTROL A UPPER LIMIT POSITION Turn on power supply or press microswitch approx 2 sec when power is on Motor will make a sound Roller shutter will make an up down...

Страница 5: ...limit position will be set Then the motor will move in the opposite direction When the roller shutters reaches the lower limit position the motor will feel resistance stop and set the lower end posit...

Страница 6: ...rd limit position has been set The third limit position has been removed Limit positions has been removed Press STOP button Press STOP button Motor will make a sound Roller shutters will make short up...

Страница 7: ...ake a several short sounds Press and hold STOP button on the B remote control for 2 seconds 14 Deleting another transmitter 15 Deleting all transmitters Motor will make a sound Roller shutters will ma...

Страница 8: ...s If the motor performs two short up down movements and make two sounds it means that the motor is in mode 2 The sensitivity of obstacle detection is reduced to 10 cm from the upper and lower limit po...

Отзывы: