4-9
IM 760401-01E
Setting Measurement Conditions and Measurement Range
4
• The maximum display is 99999 (when the number of displayed digits is set to 5).
• When the result of “voltage range
×
current range” exceeds 1000 W, the unit on the
display will change to “kW”; When this result exceeds 1000 kW, the unit on the
display will change to MW.
Power range table
• A list of the combination of voltage and current ranges and the power range are
shown below. The table shows the active power range (unit: W). The same
ranges are set for apparent power (unit: VA) and reactive power (unit: var). Just
replace the unit with VA or var when looking at the tables.
• The following table shows the case when the number of displayed digits is five.
When the number of displayed digits is set to four, one digit is subtracted to the
lowest digit of the values in the table. For selecting the number of displayed digits,
see section 4.13.
On the WT230
• When the crest factor is set to 3
Wiring System
Voltage
Current Range
Range (V)
500.00 mA
1.0000 A
2.0000 A
5.0000 A
10.000 A
20.000 A
Single-phase, two-wire
15.000
7.5000 W
15.000 W
30.000 W
75.000 W
150.00 W
300.00 W
(1P2W)
30.000
15.000 W
30.000 W
60.000 W
150.00 W
300.00 W
600.00 W
60.000
30.000 W
60.000 W
120.00 W
300.00 W
600.00 W
1.2000 kW
150.00
75.000 W
150.00 W
300.00 W
750.00 W
1.5000 kW 3.0000 kW
300.00
150.00 W
300.00 W
600.00 W
1.5000 kW
3.0000 kW 6.0000 kW
600.00
300.00 W
600.00 W
1.2000 kW
3.0000 kW
6.0000 kW 12.000 kW
Single-phase, three-wire
15.000
15.000 W
30.000 W
60.000 W
150.00 W
300.00 W
600.00 W
(1P3W),
30.000
30.000 W
60.000 W
120.00 W
300.00 W
600.00 W
1.2000 kW
Three-phase, three-wire
60.000
60.000 W
120.00 W
240.00 W
600.00 W
1.2000 kW 2.4000 kW
(3P3W),
150.00
150.00 W
300.00 W
600.00 W
1.5000 kW
3.0000 kW 6.0000 kW
Three voltage, three current 300.00
300.00 W
600.00 W
1.2000 kW
3.0000 kW
6.0000 kW 12.000 kW
(3V3A)
600.00
600.00 W
1.2000 kW
2.4000 kW
6.0000 kW
12.000 kW 24.000 kW
Three-phase, four-wire
15.000
22.500 W
45.000 W
90.000 W
225.00 W
450.00 W
900.00 W
(3P4W)
30.000
45.000 W
90.000 W
180.00 W
450.00 W
900.00 W
1.8000 kW
60.000
90.000 W
180.00 W
360.00 W
900.00 W
1.8000 kW 3.6000 kW
150.00
225.00 W
450.00 W
900.00 W
2.2500 kW
4.5000 kW 9.0000 kW
300.00
450.00 W
900.00 W
1.8000 kW
4.5000 kW
9.0000 kW 18.000 kW
600.00
900.00 W
1.8000 kW
3.6000 kW
9.0000 kW
18.000 kW 36.000 kW
• When the crest factor is set to 6
Wiring System
Voltage
Current Range
Range (V)
250.00 mA
500 MA
1.0000 A
2.5000 A
5.0000 A
10.000 A
Single-phase, two-wire
7.5000
1.8750 W
3.7500 W
7.5000 W
18.750 W
37.500 W
75.000 W
(1P2W)
15.000
3.7500 W
7.5000 W
15.000 W
37.500 W
75.000 W
150.00 W
30.000
7.5000 W
15.000 W
30.000 W
75.000 W
150.00 W
300.00 W
75.000
18.750 W
37.500 W
75.000 W
187.50 W
375.00 W
750.00 W
150.00
37.500 W
75.000 W
150.00 W
375.00 W
750.00 W
1.5000 kW
300.00
75.000 W
150.00 W
300.00 W
750.00 W
1.5000 kW 3.0000 kW
Single-phase, three-wire
7.5000
3.7500 W
7.5000 W
15.000 W
37.500 W
75.000 W
150.00 W
(1P3W),
15.000
7.5000 W
15.000 W
30.000 W
75.000 W
150.00 W
300.00 W
Three-phase, three-wire
30.000
15.000 W
30.000 W
60.000 W
150.00 W
300.00 W
600.00 W
(3P3W),
75.000
37.500 W
75.000 W
150.00 W
375.00 W
750.00 W
1.5000 kW
Three voltage, three current 150.00
75.000 W
150.00 W
300.00 W
750.00 W
1.5000 kW 3.0000 kW
(3V3A)
75.000
150.00 W
300.00 W
600.00 W
1.5000 kW
3.0000 kW 6.0000 kW
Three-phase, four-wire
7.5000
5.6250 W
11.250 W
22.500 W
56.250 W
112.50 W
225.00 W
(3P4W)
3.7500
11.250 W
22.500 W
45.000 W
112.50 W
225.00 W
450.00 W
30.000
22.500 W
45.000 W
90.000 W
225.00 W
450.00 W
900.00 W
75.000
56.250 W
112.50 W
225.00 W
562.50 W
1.1250 kW 2.2500 kW
150.00
112.50 W
225.00 W
450.00 W
1.1250 kW
2.2500 kW 4.5000 kW
300.00
225.00 W
450.00 W
900.00 W
2.2500 kW
4.5000 kW 9.0000 kW
4.4 Selecting the Measurement Range When Using Direct Input
Содержание WT210
Страница 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Страница 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Страница 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Страница 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Страница 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...