14-25
IM 760401-01E
Communication Commands 2 (System of Commands Complying to the IEEE 488.2-1992 Standard)
14
INTEGrate:STOP
Function
Stops integration.
Syntax
INTEGrate:STOP
Example
INTEGRATE:STOP
INTEGrate:TIMer
Function
Sets the integration timer/queries the current
setting.
Syntax
INTEGrate:TIMer {<NRf>,<NRf>,<NRf>|
<String>}
{<NRf>,<NRf>,<NRf>}=0,0,0 to
10000,0,0
{<String>}=HHHHH:MM:SS HHHHH hour MM
minute SS second
Example
INTEGRATE:TIMER 10,0,0
INTEGRATE:TIMER "10:00:00"
INTEGRATE:TIMER? -> :INTEGRATE
:TIMER 10,0,0
INTEGrate?
Function
Queries all settings relating to integration.
Syntax
INTEGrate?
Example
INTEGRATE? -> :INTEGRATE:
MODE NORMAL;TIMER 0,0,0
INTEGrate:MODE
Function
Sets the integration mode/queries the current
setting.
Syntax
INTEGrate:MODE {NORMal|CONTinuous}
INTEGrate:MODE?
Example
INTEGRATE:MODE NORMAL
INTEGRATE:MODE?
-> :INTEGRATE:MODE NORMAL
INTEGrate:RESet
Function
Resets the integrated values.
Syntax
INTEGrate:RESet
Example
INTEGRATE:RESET
INTEGrate:STARt
Function
Starts integration.
Syntax
INTEGrate:STARt
Example
INTEGRATE:START
HARMonics:THD
Function
Sets the computation method for harmonic
distortion (THD) for harmonic measurement/
queries the current setting.
Syntax
HARMonics:THD {IEC|CSA}
HARMonics:THD?
Example
HARMONICS:THD IEC
HARMONICS:THD? -> :HARMONICS:THD IEC
14.3.7 INTEGrate Group
The commands in the INTEGrate group are used to make settings relating to, and inquiries about integration. This
allows you to make the same settings and inquiries as when using the START key, STOP key, RESET key, INTEG
SET key and their corresponding menus.
:INTEGrate
:
MODE
<Space>
NORMal
CONTinuous
?
TIMer
<Space>
<NRf>
,
<NRf>
,
<NRf>
?
STARt
STOP
RESet
?
<Character string>
;
HARMonics:SYNChronize
Function
Sets the fundamental frequency for PLL
synchronization (PLL source)/queries the
current setting.
Syntax
HARMonics:SYNChronize
{(V|A),(<NRf>|ELEMent<1-3>)}
HARMonics:SYNChronize?
Example
HARMONICS:SYNCHRONIZE V,1
HARMONICS:SYNCHRONIZE?
-> :HARMONICS:SYNCHRONIZE V,1
14.3 Commands
Содержание WT210
Страница 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Страница 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Страница 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Страница 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Страница 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...