6-3
IM 760401-01E
Integration
6
Display Resolution during Integration
The display resolution of integrated values is normally 99999 counts (counts up to
999999 only when the unit is MWh or MAh). When the integrated value reaches 100000
counts, the decimal point shifts automatically. For example, if 0.0001 mWh is added to
9.9999 mWh, the display shows “10.000 mWh.”
Display Function of Integrator Values
By selecting the display function, you can display the polarity of the integrator values.
Display function
Measurement mode
Display contents
Wh
RMS, VOLTAGE MEAN, DC both positive and negative watt hour values
Wh
±
*1
RMS, VOLTAGE MEAN, DC positive watt hour value
Wh
±
*1
RMS, VOLTAGE MEAN, DC negative watt hour value
Ah
RMS, VOLTAGE MEAN
total ampere hour values
DC
both positive and negative ampere hour values
Ah
±
*2
RMS, VOLTAGE MEAN
total ampere hour values (same as Ah)
DC
positive ampere hour value
Ah
±
*2
RMS, VOLTAGE MEAN
–0
DC
negative ampere hour value
*1 When the Wh function is selected, pressing the FUNCTION key once or twice will result in
Wh
±
. Pressing the FUNCTION key once will result in displaying the positive watt hour value,
whereas pressing the FUNCTION key twice will result in displaying the negative watt hour
value. In case of the negative watt hour value, “–” will appear in front of the value.
*2 When the Ah function is selected, pressing the FUNCTION key once or twice will result in
Ah
±
. Pressing the FUNCTION key once will result in displaying the positive ampere hour
value, whereas pressing the FUNCTION key twice will result in displaying the negative
ampere hour value. In case of the negative ampere hour value, “–” will appear in front of the
value.
Note
•
When negative integrated values are displayed, the minimum display reading will become –
99999 MWh/MAh because of the added minus character.
•
During integration is in progress (until being reset), operation of other functions are restricted.
Refer to page 6-10 for more details.
6.1 Integrator Functions
Содержание WT210
Страница 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Страница 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Страница 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Страница 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Страница 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...