5-43
IM 760101-11E
Commands
5
:HCOPy:PRINter:DLISt:HARMonics:
ELEMent<x>
Function
Turns ON/OFF the output of the element when
printing the numerical data list using the built-in
printer during harmonic measurement or queries
the current setting.
Syntax
:HCOPy:PRINter:DLISt:HARMonics:
ELEMent<x> {<Boolean>}
:HCOPy:PRINter:DLISt:HARMonics:
ELEMent<x>?
<x> = 1 to 6
Example
:HCOPY:PRINTER:DLIST:HARMONICS:
ELEMENT1 ON
:HCOPY:PRINTER:DLIST:HARMONICS:
ELEMENT1? -> :HCOPY:PRINTER:DLIST:
HARMONICS:ELEMENT1 1
:HCOPy:PRINter:DLISt:HARMonics:
{<Harmonic measurement function>|SIGMa|
UHDF|IHDF|PHDF}
Function
Turns ON/OFF the output of the function when
printing the numerical data list using the built-in
printer during harmonic measurement or queries
the current setting.
Syntax
:HCOPy:PRINter:DLISt:HARMonics:
{<Harmonic measurement function>|
SIGMa|UHDF|IHDF|PHDF} {<Boolean>}
:HCOPy:PRINter:DLISt:HARMonics:
{<Harmonic measurement function>|
SIGMa|UHDF|IHDF|PHDF}?
<Harmonic measurement function> =
{U|I|P|
S|Q|LAMBda...}
(See the function selection
list (3) of “DISPlay group.”)
SIGMa =
Σ
List (dedicated to numerical data list
printing)
UHDF = Uhdf (dedicated to bar graph printing)
IHDF = Ihdf (dedicated to bar graph printing)
PHDF = Phdf (dedicated to bar graph printing)
Example
:HCOPY:PRINTER:DLIST:HARMONICS:U ON
:HCOPY:PRINTER:DLIST:HARMONICS:U?
-> :HCOPY:PRINTER:DLIST:HARMONICS:
U 1
Description The command and query using “
:HCOPy:
PRINter:DLISt:HARMonics:SIGMa
” is valid
on models with two or more elements.
:HCOPy:PRINter:DLISt:INFOrmation
Function
Sets whether or not to add setup parameters
when printing the numerical data list using the
built-in printer or queries the current setting.
Syntax
:HCOPy:PRINter:DLISt:
INFOrmation {<Boolean>}
:HCOPy:PRINter:DLISt:INFOrmation?
Example
:HCOPY:PRINTER:DLIST:INFORMATION ON
:HCOPY:PRINTER:DLIST:INFORMATION?
-> :HCOPY:PRINTER:DLIST:
INFORMATION 1
:HCOPy:PRINter:DLISt:NORMal?
Function
Queries all settings related to the printing of the
numerical data list for normal measurement.
Syntax
:HCOPy:PRINter:DLISt:NORMal?
Example
:HCOPY:PRINTER:DLIST:NORMAL? ->
:HCOPY:PRINTER:DLIST:NORMAL:
ELEMENT1 1;ELEMENT2 0;ELEMENT3 0;
ELEMENT4 0;ELEMENT5 0;ELEMENT6 0;
SIGMA 0;SIGMB 0;SIGMC 0;URMS 1;
UMN 1;UDC 1;UAC 1;IRMS 1;IMN 1;
IDC 1;IAC 1;P 1;S 1;Q 1;LAMBDA 1;
PHI 1;FU 1;FI 1;UPPEAK 1;UMPEAK 1;
IPPEAK 1;IMPEAK 1;CFU 1;CFI 1;
FFU 1;FFI 1;Z 1;RS 1;XS 1;RP 1;
XP 1;PC 1;TIME 0;WH 0;WHP 0;WHM 0;
AH 0;AHP 0;AHM 0;ETA 0;SETA 0;F1 0;
F2 0;F3 0;F4 0;DURMS 0;DUMN 0;
DUDC 0;DUAC 0;DIRMS 0;DIMN 0;
DIDC 0;DIAC 0
:HCOPy:PRINter:DLISt:NORMal:ALL
Function
Collectively turns ON/OFF the output of all
elements and functions when printing the
numerical data list using the built-in printer
during normal measurement.
Syntax
:HCOPy:PRINter:DLISt:NORMal:
ALL {<Boolean>}
Example
:HCOPY:PRINTER:DLIST:NORMAL:ALL ON
:HCOPy:PRINter:DLISt:NORMal:{ELEMent<x>|
SIGMA|SIGMB|SIGMC}
Function
Turns ON/OFF the output of the
{element|
Σ
A|
Σ
B|
Σ
C}
when printing the numerical data
list using the built-in printer during normal
measurement or queries the current setting.
Syntax
:HCOPy:PRINter:DLISt:NORMal:
{ELEMent<x>|SIGMA|SIGMB|
SIGMC} {<Boolean>}
:HCOPy:PRINter:DLISt:NORMal:
{ELEMent<x>|SIGMA|SIGMB|SIGMC}?
<x> = 1 to 6
Example
:HCOPY:PRINTER:DLIST:NORMAL:
ELEMENT1 ON
:HCOPY:PRINTER:DLIST:NORMAL:
ELEMENT1? -> :HCOPY:PRINTER:DLIST:
NORMAL:ELEMENT1 1
Description • The command and query using “
:HCOPy:
PRINter:DLISt:NORMal:SIGMB
” is valid
on models with two or more elements.
• The command and query using “
:HCOPy:
PRINter:DLISt:NORMal:SIGMC
” is valid
on models with three or more elements.
5.8 HCOPy Group
Содержание wt1600
Страница 1: ...Digital Power Meter Communication Interface IM 760101 11E 4th Edition ...
Страница 131: ...7 2 IM 760101 11E 7 2 Sample Program Image ...
Страница 138: ...Sample Program 7 9 IM 760101 11E 7 7 4 Output of Normal Measurement Data ...
Страница 142: ...Sample Program 7 13 IM 760101 11E 7 7 5 Output of Harmonic Measurement Data ...