<2. Notes on Handling>
2-4
IM 01W07D01-01EN
WARNING
The battery pack may be replaced in a
hazardous area. The battery pack has
surface resistivity greater than 1G ohm and
must be properly installed in the enclosure
of the transmitter. Care must be taken during
transportation to and from the point of installation
to prevent electrostatic charge build-up.
2.6.1 ATEX Certification
(1) Technical Data
Caution for ATEX Intrinsically safe type.
Note 1. Model WN100 Wireless Sound Level Meter
with optional code /KS27 for potentially
explosive atmospheres:
• No. Presafe 19 ATEX 14009X
• Applicable Standard:
EN 60079-0: 2012+A11: 2013
EN IEC 60079-0:2018
EN 60079-11: 2012
EN 60079-28: 2015
• Type of Protection and Marking code
II 1 G Ex ia op is IIC T4 Ga
• Group: II
• Category: 1 G
• Ambient Temperature: –40°C to 70°C
Note 2. Installation
• Installation shall be in accordance with relevant
national and/or local installation codes and IEC
(EN) 60079-14.
(Refer to the Control Drawing)
• The following conditions must be met for the
antenna connector.
(total Li of simple apparatus) + (total Lc) ≤ 1 mH
(total Ci of simple apparatus) + (total Cc) ≤ 1 μF
• The temperature class of Antenna must be
determined from Po = 10 mW at Antenna
Connector.
[Control Drawing]
WN100
Hazardous area
Battery
pack
Antenna Connector
Antenna
(Note 1)
Microphone
Microphone Connector
F0204.ai
Note 1 This apparatus is simple apparatus.
WARNING
Specific conditions of Use
• Electrostatic charges on the non-metallic
parts (excluding glass parts) or the coated
parts of the equipment, or on non-metallic
parts of accessories shall be avoided.
When the equipment is used in hazardous
areas, avoid any actions which generate
electrostatic charges, such as rubbing with a
dry cloth.
• The enclosure contains aluminum and is
considered a potential risk of ignition caused
by impact or friction. When the equipment is
used in a potentially explosive atmosphere
requiring equipment category 1 G, it must be
installed such that, even in the event of rare
incidents, ignition sources due to impact and/
or friction sparks are excluded.
• The circuit of WN100 is connected to the
enclosure and not insulated from earth.
WARNING
• Use only YOKOGAWA BATTERY PACK
F9915MA or F9915NS
• Do not replace the battery cells is hazardous
area.
• Potential electrostatic charging hazard
Содержание WN100
Страница 1: ...User s Manual WN100 Wireless Sound Level Meter IM 01W07D01 01EN IM 01W07D01 01EN 1st Edition ...
Страница 2: ......
Страница 15: ... 3 Component Names 3 2 IM 01W07D01 01EN Infrared port F0302 ai Figure 3 2 Infrared port ...
Страница 56: ... 10 Connecting Sensor 10 8 IM 01W07D01 01EN 10 6 Infrared Configuration Infrared port F1006 ai ...
Страница 58: ......
Страница 59: ......