<1. General Information>
1-1
IM 12Y18A03-01EN
1st Edition : Oct. 04, 2019-00
1. General Information
This user guide covers the operation, maintenance and troubleshooting for the WE430 Hydrazine
analyzer, which offers unmatched reliability in analyzing oxygen scavengers in feedwater, boiler
water or at the economizer inlet.
n
Introduction
Analyzer the oxygen scavenger content at points in the steam/water circuit where dissolved
oxygen control is critical. Residual oxygen scavengers must be carefully monitored to prevent
costly overdosing, yet allow enough of the reductant in the system for metal passivation.
Excess levels of certain oxygen scavengers decompose into ammonia, which increases system
alkalinity. Efficient control of oxygen scavengers depends on maintaining a predetermined safety
zone. The WE430 Hydrazine analyzer optimizes the fluidic design with the sensing technology
to provide accurate and precise results with an almost instantaneous indication of oxygen
scavenger concentration changes.
The WE430 Hydrazine analyzer meets all of the criteria for accurate and dependable oxygen
scavenger monitoring and more. The WE430 analyzer incorporates innovative technologies that
include:
• Premium electrodes
• Marquee help screen
• Pump-less reagent addition and dynamic calibration system
l
Markets
• Power
• Pulp and paper
• Chemical / petrochemical
l
Applications
• Boiler water
• Feedwater
• Hydrazine
• Carbohydrazide
• DEHA and others
n
Features and Benefits
The WE430 Hydrazine analyzer is ideal for measuring and monitoring the critical oxygen
scavenger levels in feedwater, boiler water or economizer inlet. With limited maintenance
requirements and low reagent usage, the WE430 analyzer provides the highest level of
performance with easy of use.
• Measurement of oxygen scavenger concentrations in water using premium ion selective
electrode (ISE) technology.
• Accurate and precise measurements in the range of 0 ppb to 200 ppb for hydrazine:
• Reliable measurements and a wide measurement range with selectable resolution.
• Measures oxygen scavenger activity in aqueous solutions quickly, accurately and
economically.
• Premium reference and sensing electrodes:
• Superior accuracy and stability over a wide temperature range.
• Advanced flow cell design:
• Automatic sample handling and contamination control with no moving parts.
• Patented scrolling marquee:
• Intuitive menu-driven, digital user interface.
• Data log of previous measurements and calibration:
• View measurement, calibration and error history.