6. PARAMETERS
6.1 Vortex Flowmeter VY Series
Parameters
The internal parameters of the Vortex Flowmeter
VY Series are set to their defaults before shipment
from the factory, except when specified otherwise
when the order is placed.
Change and set the measured fluid, contact outputs
and display indication, if necessary.
IMPORTANT
Settings will be canceled if the flowmeter is turned
OFF within 30 seconds of changing settings.
After changing settings, be sure to wait at least 30
seconds before turning the flowmeter OFF.
6.2 Configuration of Parameters
Item A (menu A): Process Variables
Item B (menu B): Easy Setup
Item C (menu C): Basic Setup
Item D (menu D): Additional Setup
Item E (menu E): Sensor Setup
Item F (menu F): Compensation Setup
Item G (menu G): Temperature/Pressure
Measurement Setup
Item H (menu H): Adjustment Functions
Item J (menu J): Test/Simulation
Item K (menu K): Maintenance
In addition, for details on "Parameter List"
and "Parameter Description", read the
Communications Manual in the related documents
indicated in Table 1.1.
Parameter information unique to the device is held
as data on the pre-amplifier inside the sensor,
and can be restored based on that data when
the remote transmitter is replaced, for example.
For details on how to back up and restore data,
read the Communications Manual in the related
documents indicated in Table 1.1.
<6. Parameters>
33
IM 01F07A01-01EN
Parameters
6
Basic Operating Procedures (Display)
5