User’s
Manual
IM 04L51B01-18EN
1st Edition
Model GX10/GP10/GX20/GP20
EtherNet/IP Communication (/E1)
User’s Manual
Страница 1: ...User s Manual IM 04L51B01 18EN 1st Edition Model GX10 GP10 GX20 GP20 EtherNet IP Communication E1 User s Manual...
Страница 2: ...ct your nearest YOKOGAWA dealer Copying or reproducing all or any part of the contents of this manual without the permission of YOKOGAWA is strictly prohibited Trademarks vigilantplant and SMARTDAC ar...
Страница 3: ...cause light injury to the user or cause damage to the instrument or user s data and precautions that can be taken to prevent such occurrences Note Calls attention to information that is important for...
Страница 4: ...d The basic items for this configuration are explained For the operation procedures of Rockwell Automation products see the user s manuals of these products This manual is intended for those who have...
Страница 5: ...ble Connection 3 Settings of the GX GP 3 Preparation for PLC 4 EDS File 4 System Configuration 4 Explicit Message 5 System Configuration on PLC 5 Data on the GX GP 16 I O Messages 17 System Configurat...
Страница 6: ...ents Scanner Client A device that launches a request on EtherNet IP This is either a PLC or PC For the GX GP PLCs such as Allen Bradley PLC 2 PLC 5 SLC 500 MicroLogix CompactLogix and ControlLogix rep...
Страница 7: ...ress and other settings required to connect to Ethernet Enabling of EtherNet IP server function Access to the GX GP The GX GP is a passive device on an Ethernet network The GX GP cannot launch a reque...
Страница 8: ...n EtherNet IP Server Settings Path GX GP MENU key Browse tab Setting Setting menu Communication Ethernet settings Server settings Server list Web browser Config tab Communication Ethernet settings Ser...
Страница 9: ...guration tool see the user s manual of the configuration tool EtherNet IP GX GP Scanner Client Adapter Server PLC Configuration tool Read Write message Ethernet EDS file How to Obtain the EDS File Obt...
Страница 10: ...g an MSG instruction specify a command The GX GP supports the following commands Target PLC Command name PLC 2 PLC2 Unprotected Read Write PLC 5 PLC5 Word Range Read Write PLC5 Typed Read Write SLC SL...
Страница 11: ...201 1600 1250 1649 1301 1650 1350 1699 1401 1700 1450 1749 1501 1750 1550 1799 Expandable I O 2 2001 2000 2050 2049 2101 2050 2150 2099 2201 2100 2250 2149 2301 2150 2350 2199 2401 2200 2450 2249 2501...
Страница 12: ...9 4301 3150 4350 3199 4401 3200 4450 3249 4501 3250 4550 3299 Expandable I O 5 5001 3500 5050 3549 5101 3550 5150 3599 5201 3600 5250 3649 5301 3650 5350 3699 5401 3700 5450 3749 5501 3750 5550 3799 E...
Страница 13: ...560 0610 4569 0701 4570 0710 4579 0801 4580 0810 4589 0901 4590 0910 4599 Computation channel A001 5000 A100 5099 Communication channel Read Write C001 6000 C500 6499 stands for data in numerical orde...
Страница 14: ...2 00 0450 N12 49 L12 49 F12 49 0501 N12 50 L12 50 F12 50 0550 N12 99 L12 99 F12 99 0601 N13 00 L13 00 F13 00 0650 N13 49 L13 49 F13 49 0701 N13 50 L13 50 F13 50 0750 N13 99 L13 99 F13 99 0801 N14 00 L...
Страница 15: ...001 N25 00 L25 00 F25 00 3050 N25 49 L25 49 F25 49 3101 N25 50 L25 50 F25 50 3150 N25 99 L25 99 F25 99 3201 N26 00 L26 00 F26 00 3250 N26 49 L26 49 F26 49 3301 N26 50 L26 50 F26 50 3350 N26 99 L26 99...
Страница 16: ...50 L36 50 F36 50 5350 N36 99 L36 99 F36 99 5401 N37 00 L37 00 F37 00 5450 N37 49 L37 49 F37 49 5501 N37 50 L37 50 F37 50 5550 N37 99 L37 99 F37 99 Expandable I O 6 6001 N40 00 L40 00 F40 00 6050 N40 4...
Страница 17: ...5 70 0710 N45 79 L45 79 F45 79 0801 N45 80 L45 80 F45 80 0810 N45 89 L45 89 F45 89 0901 N45 90 L45 90 F45 90 0910 N45 99 L45 99 F45 99 Computation channel A001 N50 00 L50 00 F50 00 A100 N50 99 L50 99...
Страница 18: ...1199 dint 1199 real 1199 0401 int 1200 dint 1200 real 1200 0450 int 1249 dint 1249 real 1249 0501 int 1250 dint 1250 real 1250 0550 int 1299 dint 1299 real 1299 0601 int 1300 dint 1300 real 1300 0650...
Страница 19: ...nt 2549 real 2549 3101 int 2550 dint 2550 real 2550 3150 int 2599 dint 2599 real 2599 3201 int 2600 dint 2600 real 2600 3250 int 2649 dint 2649 real 2649 3301 int 2650 dint 2650 real 2650 3350 int 269...
Страница 20: ...eal 3699 5401 int 3700 dint 3700 real 3700 5450 int 3749 dint 3749 real 3749 5501 int 3750 dint 3750 real 3750 5550 int 3799 dint 3799 real 3799 Expandable I O 6 6001 int 4000 dint 4000 real 4000 6050...
Страница 21: ...al 5000 A100 int 5099 dint 5099 real 5099 Communication channel Read Write C001 int 6000 dint 6000 real 6000 C500 int 6499 dint 6499 real 6499 stands for data in numerical order The continuous channel...
Страница 22: ...to 0250 0301 to 0350 Producer 102 400 4 x 100 INT32 0401 to 0450 0501 to 0550 Producer 103 400 4 x 100 INT32 0601 to 0650 0701 to 0750 Producer 104 400 4 x 100 INT32 0801 to 0850 0901 to 0950 Produce...
Страница 23: ...400 4 x 100 INT32 Computation channel A001 to A100 Producer 137 400 4 x 100 INT32 Communication channel Read Write C001 to C100 Producer Consumer 138 400 4 x 100 INT32 C101 to C200 Producer Consumer...
Страница 24: ...o 2350 Producer 159 400 4 x 100 FLOAT 2401 to 2450 2501 to 2550 Producer 160 400 4 x 100 FLOAT Expandable I O 3 3001 to 3050 3101 to 3150 Producer 163 400 4 x 100 FLOAT 3201 to 3250 3301 to 3350 Produ...
Страница 25: ...T C301 to C400 Producer Consumer 188 400 4 x 100 FLOAT C401 to C500 Producer Consumer 189 400 4 x 100 FLOAT Configuration 195 0 Producer Consumer 196 0 The continuous channel data area is a special ar...
Страница 26: ...IP Access to Non existent Data If non existent data is accessed either of the following operations occur 0 is read if non existent data is read Nothing is done if non existent data is written Special...
Страница 27: ...PCCC Data Table 5 Authentication File No 11246 01 Jan 21 2014 1 A session a framework of connection management in the encapsulation protocol layer of EtherNet IP provides similar functions as a TCP co...
Страница 28: ...der Element toolbar to select MSG The MSG block is inserted as ladder output Tag MSG1 is assigned to the MSG block MSG MSG1 EN Message Control Message DN ER Make the MSG block settings Click the butto...
Страница 29: ...e connection path in the Communication tab is not replaced either I O Con guration Ethernet ETHERNET MODULE GX Message Launch Logic Lastly configure the message launch logic In the example shown in th...
Страница 30: ...ng shows an example of reading data in input output channels 0001 to 0010 and writing the data to communication channel data C001 to C020 Data can be accessed using the INT32 type In the Name field en...
Страница 31: ...Blank...