8-15
IM 704420-01E
Communication Function
8
8.7
Commands
8.7.1 A List of Commands
Command
Function
Page
CALCulation Group
:CALCulation:AVERage?
Queries the average value.
8-18
:CALCulation:ELERror?
Queries the Effect Length Error.
8-18
:CALCulation:FLUTter?
Queries the
σ
/AVE value.
8-18
:CALCulation:JITTer?
Queries the jitter ratio.
8-18
:CALCulation:MAXimum?
Queries the maximum value.
8-18
:CALCulation:MELE?
Queries the MELE value.
8-18
:CALCulation:MINimum?
Queries the minimum value.
8-18
:CALCulation:PHASe?
Queries the phase difference between the data signal and the clock signal.
8-18
:CALCulation:PTOPeak?
Queries the P-P value.
8-18
:CALCulation:SDEViation?
Queries the standard deviation (jitter
σ
).
8-18
:CALCulation:SNUMber?
Queries the number of samples of the data signal.
8-19
:CALCulation:TVALue?
Queries the period of the clock signal.
8-19
COMMunicate Group
:COMMunicate?
Queries all settings related to communications.
8-20
:COMMunicate:HEADer
Sets whether or not to attach a header to the response data or
queries the current setting (ON/OFF).
8-20
:COMMunicate:VERBose
Sets the response messages to full form or abbreviated form or queries the
current setting.
8-20
:COMMunicate:WAIT
Waits for a specified extended event.
8-20
:COMMunicate:WAIT?
Creates the response that is returned when the specified event occurs.
8-20
DCOut Group
:DCOut?
Queries all settings related to the DC output of the jitter ratio.
8-21
:DCOut:JITTer:COEFficient
Sets the jitter ratio correction coefficient or queries the current setting.
8-21
:DCOut:JITTer:CYCLe
Sets the average coefficient of the DC output of the jitter ratio or queries the
current setting.
8-21
:DCOut:JITTer:RANGe
Sets the upper and lower limits of the DC output of the jitter ratio or queries
the current setting.
8-21
:DCOut:JUDGe:LEVel
Sets the determination level or queries the current setting.
8-21
:DCOut:JUDGe:RESult?
Queries the determination result.
8-22
:DCOut:MODE
Sets the DC output mode or queries the current setting.
8-22
DISPlay Group
:DISPlay?
Queries all settings related to the analog meter.
8-22
:DISPlay:MEASure
Sets the measured value to be displayed or queries the current setting.
8-22
:DISPlay:SCALe
Sets the scale of the analog meter or queries the current setting.
8-22
:DISPlay:STATistic
Turns ON/OFF the numeric display or queries the current setting.
8-22
INPut Group
:INPut?
Queries all settings related to the input signal.
8-24
:INPut:CLOCk?
Queries all settings related to the clock signal input.
8-24
:INPut:CLOCk:DELay?
Queries all settings related to the phase delay of the clock signal.
8-24
:INPut:CLOCk:DELay:TIME
Sets the phase delay time of the clock signal or queries the current setting.
8-24
:INPut:CLOCk:SLOPe
Sets the slope of the clock signal or queries the current setting.
8-24
:INPut:DATA:POLarity
Sets the polarity of the data signal or queries the current setting.
8-24
:INPut:DATA:TRIGger?
Queries all settings related to the trigger.
8-24
:INPut:DATA:TRIGger:MODE
Sets the trigger mode or queries the current setting.
8-24
:INPut:DATA:TRIGger:LEVel
Sets the slice level or queries the current setting.
8-24
:INPut:EQ[:MODE]
Turns ON/OFF the equalizer or queries the current setting.
8-24
:INPut:PLL[:MODE]
Sets the PLL or queries the current setting.
8-25
:INPut:PLL:STATus?
Queries the lock condition (when the clock signal could be regenerated from
the data signal) of the PLL.
8-25