background image

ii

IM 04L51B01-20EN

Notes

●  The contents of this manual are subject to change without prior notice as a result of 

continuing improvements to the instrument’s performance and functions.

●  Every effort has been made in the preparation of this manual to ensure the accuracy of its 

contents. However, should you have any questions or find any errors, please contact your 

nearest YOKOGAWA dealer.

●  Copying or reproducing all or any part of the contents of this manual without 

YOKOGAWA’s permission is strictly prohibited.

QR Code

The product has a QR Code pasted for efficient plant maintenance work and asset 

information management.

It enables confirming the specifications of purchased products and user’s manuals.

For more details, please refer to the following URL.

https://www.yokogawa.com/qr-code

QR Code is a registered trademark of DENSO WAVE INCORPORATED.

Trademarks

●  S is registered trademarks of Yokogawa Electric Corporation.

●  Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation 

in the United States and other countries.

●  Adobe and Acrobat are registered trademarks or trademarks of Adobe Systems 

Incorporated.

●  Kerberos is a trademark of Massachusetts Institute of Technology (MIT).

●  RC4 is a registered trademark of RSA Security Inc. in the United States and other 

countries.

●  Company and product names that appear in this manual are registered trademarks or 

trademarks of their respective holders.

●  The company and product names used in this manual are not accompanied by the 

registered trademark or trademark symbols (® and ™).

About the Usage of Open Source Software

This product uses open source software.

For details on using open source software, see IM 04L61B01-11EN (

Regarding the 

Downloading and Installing for the Software, Manuals and Labels

).

Revisions

December 2015

1st Edition

March 2016

2nd Edition

June 2017

3rd Edition

May 2020

4th Edition

July 2021

5th Edition

 

Содержание SMARTDAG+ GX10

Страница 1: ...User s Manual IM 04L51B01 20EN 5th Edition Model GX10 GX20 GP10 GP20 GM10 OPC UA Server E3 User s Manual...

Страница 2: ......

Страница 3: ...cquisition System Advanced Security Function AS User s Manual IM 04L55B01 05EN Describes how to use the advanced security function AS option GX GP GM Model GX10 GX20 GP10 GP20 GM10 Communication Comma...

Страница 4: ...Trademarks SMARTDAC is registered trademarks of Yokogawa Electric Corporation Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the United States and other cou...

Страница 5: ...ion GX GP User s Manual Model GX10 GX20 GP10 GP20 Paperless Recorder User s Manual Refers to the IM 04L51B01 01EN GX GP First Step Guide Model GX10 GX20 GP10 GP20 Paperless Recorder First Step Guide R...

Страница 6: ...ons that could cause light injury to the user or cause damage to the instrument or user s data and precautions that can be taken to prevent such occurrences Note Calls attention to information that is...

Страница 7: ...number 1 3 GX GP Release number 4 Version 4 01 Support for PID control module has been added Style number 2 GM10 Release number 4 Version 4 01 Style number 1 4 GX GP Release number 4 Version 4 08 Supp...

Страница 8: ...Overview 1 1 OPC UA Server E3 Specifications 1 2 Communication Specifications 1 2 Security 1 3 GX GP GM Configuration 1 5 OPC UA Server Function 1 5 Others 1 5 GX GP GM Data Structure 1 6 Entire Stru...

Страница 9: ...m that is linked to production sites to grasp and manage production process status provide instructions and aid to operators and the like Features Incorporation of the OPC UA server function allows ea...

Страница 10: ...r type Data Access Server DA Profile Micro Embedded Device Server Maximum number of items GX20 GP20 GM10 300 MonitoredItem Session GX10 GP10 100 MonitoredItem Session Maximum number of subscriptions 3...

Страница 11: ...tion Method Description Anonymous authentication No authentication Username authentication Authentication by user name1 2 and password1 1 The user name and password set with the GX GP GM security func...

Страница 12: ...User Only data reading is allowed Read Admin Data reading and writing are allowed Read Write SecondAdmin1 Only data reading is allowed Read Monitor 1 Only data reading is allowed Read 1 Only for the...

Страница 13: ...ion Description On The OPC UA server function is enabled Off The OPC UA server function is disabled Port number Set the port that the OPC UA server will use Unless specified otherwise you do not need...

Страница 14: ...an OPC UA server An OPC UA client can access a GX GP GM and view the address space in order to write and read from required nodes monitor data and so on Entire Structure Device GX10 1 IP address or ho...

Страница 15: ...hannel data Float Read Write All Alarm Status Status of all alarms Boolean Read Only If any alarm status is true this is set to true Alarm Status 1 to 4 Status of each alarm Boolean Read Only Alarm SP...

Страница 16: ...Communication channel 0001 All channel alarm status Alarm level 1 status Alarm level 2 status Alarm level 3 status Alarm level 4 status Channel data C0001_Setting C0001_Alarm_Setting C0001_Alarm01_SP...

Страница 17: ...hannel I O channel 0001 All channel alarm status Alarm level 1 status Alarm level 2 status Alarm level 3 status Alarm level 4 status Channel data CH0001_Setting CH0001_Alarm_Setting CH0001_Alarm01_SP...

Страница 18: ...0 Math channel 0001 All channel alarm status Alarm level 1 status Alarm level 2 status Alarm level 3 status Alarm level 4 status Channel data A0001_Setting A0001_Alarm_Setting A0001_Alarm01_SP A0001_A...

Страница 19: ...alue SP value OUT value RUN STOP switching AUTO MAN Cascade switching LOCAL REMOTE switching LP001_ALARM LP001_ALARM01 LP001_ALARM02 Alarm level 1 status in the loop LP001_ALARM03 LP001_ALARM04 Alarm...

Страница 20: ...nt01 Batch_Comment01_02 Batch_Comment01_03 Batch_No01 Batch_Group01 Batch_Comment01_01 Batch Settings Batch comment 1 Batch comment 2 Batch comment 3 Batch number Batch_Text01_01 Batch_TextField01_01...

Страница 21: ...rver but data values and status vary depending on the GX GP GM channel data and channel status The data values and status that can be acquired depending on the channel status are shown below GX GP GM...

Страница 22: ...ription Supported Functions Group Sub Group Supported Function Subscription Notification Data Change Notification Max Subscription 3 Subscription Session Min Publish Interval 100 ms Lifetime Count 3 t...

Отзывы: