Introduction

Thank you for purchasing the S GM Data 

Acquisition System (hereafter referred to as the GM). This 

manual explains the basic operation, installation, and wiring 

of the GM.

For details on configuring and operating the GM, see the GM 

Data Acquisition System User’s Manual (IM 04L55B01-01EN) 

provided in electronic format.

For details on the settings and operation of the PID control 

module and program control (/PG option), see the Loop 

Control Function, Program Control Function (/PG Option) 

User’s Manual (IM 04L51B01-31EN) and the S 

STANDARD Hardware Configurator User’s Manual (IM 

04L61B01-02EN), provided as electronic manuals.

This manual covers the following products and I/O modules 

(GX90 series).

Model

Product name

GM10

Data Acquisition Module for S GM

GM90PS

Power Supply Module for S GM

GM90MB

Module Base for S GM

This manual denotes devices with their product names or 

model (e.g. GM10).

To ensure correct use, please read this manual and the 

following manuals thoroughly before beginning operation.

Paper Manuals

Manual Title

Manual No.

Data Acquisition System GM

First Step Guide

IM 04L55B01-02EN

(this manual)

Precaution on the use of S

IM 04L51B01-91EN

(included)

Regarding the Downloading and Installing for the 

Software, Manuals and Labels

About the Usage of Open Source Software

IM 04L61B01-11EN

(included)

Electronic Manuals and General Specifications

You can download these documents from the following web 

page:

http://www.smartdacplus.com/manual/en/

  See page 4 in Precaution on the use of S (IM 

04L51B01-91EN).

Genaral Specifications

Title

General 

Specifications No.

Data Acquisition System GM

GS 04L55B01-01EN

GX90XA/GX90XD/GX90YD/GX90WD/GX90XP 

 I/O modules

GS 04L53B01-01EN

GX60 I/O Base Unit (Expandable I/O) / GX90EX 

Expansion Module

GS 04L53B00-01EN

User Registration

Thank you for purchasing YOKOGAWA products. 

We invite you to register your products in order to receive the most up 

to date product information. To register, visit the following URL.

http://www.yokogawa.com/ns/reg/

Notes

●  The contents of this manual are subject to change without 

prior notice as a result of continuing improvements to the 

instrument’s performance and functions.

●  Every effort has been made in the preparation of this 

manual to ensure the accuracy of its contents. However, 

should you have any questions or find any errors, please 

contact your nearest YOKOGAWA dealer.

●  Copying or reproducing all or any part of the contents of 

this manual without YOKOGAWA’s permission is strictly 

prohibited.

Revisions

December 2014 1st Edition

August 2015

2nd Edition

December 2015 3rd Edition

June 2017

4th Edition

Trademarks

●  S are registered trademark of Yokogawa 

Electric Corporation.

●  Microsoft and Windows are registered trademarks or 

trademarks of Microsoft Corporation in the United States 

and other countries.

●  Pentium is a registered trademark of Intel Corporation.

●  Adobe and Acrobat are registered trademarks or 

trademarks of Adobe Systems Incorporated.

●  The SD logo is a registered trademark of the SD 

association.

●  Bluetooth is a trademark or registered trademark of 

Bluetooth SIG, Inc.

●  Company and product names that appear in this manual 

are registered trademarks or trademarks of their respective 

holders.

●  The company and product names used in this manual are 

not accompanied by the registered trademark or trademark 

symbols (® and ™).

Safety Precautions

•  Read this manual and “Precaution on the use of 

S” (IM04L51B01-91EN) thoroughly and have a 

clear understanding of the product before operation.

•  This manual explains the functions of the product. It does 

not guarantee that the product will suit a particular purpose 

of the user.

•  Keep “Precaution on the use of S” and all the 

related manuals with S GM until the end of the 

use of the product.

•  When S GM contains GM10 with the optinal 

code of /C8, S GM is built in compliance with 

requirements of R&TTE Derective:

  We, Yokogawa Electric Corporation hereby declare that 

this equipment, model GM Data Acquisition system is in 

compliance with the essential requirements and other 

relevant provisions of Directive 1999/5/EC.

  The EU declaration of conformity for R&TTE for this 

product can be found at < http://www.smartdacplus.com/

manual/en/ >

•  For details on the advanced security function (/AS option), 

see the GM User’s Manual (IM 04L55B01-01EN) and 

the Advanced Security Function (/AS) User’s Manual (IM 

04L55B01-05EN).

Содержание SMARTDAC+ GM10

Страница 1: ...ail 14 Mounting on a Wall 14 Wiring 15 Precautions to Be Taken While Wiring 16 Removing andAttaching a Terminal Cover 16 Removing andAttaching a Terminal Block 16 Wiring Procedure 17 Internal dimensio...

Страница 2: ...out prior notice as a result of continuing improvements to the instrument s performance and functions Every effort has been made in the preparation of this manual to ensure the accuracy of its content...

Страница 3: ...ration or shock or pull out the card Data can become corrupt or permanently lost Only use Yokogawa SD cards Operation cannot be guaranteed with other brands of card When inserting the SD card into the...

Страница 4: ...iption GM90PS Power Supply Module for SMARTDAC GM Type 1 Always 1 Area N General Supply voltage 1 100 240V AC 2 12 28 V DC 1 Power supply connection D Power inlet with UL CSA cable F Power inlet with...

Страница 5: ...01 1 1GB Shunt resistor for M3 screw terminal 415940 1 250 0 1 415941 1 100 0 1 415942 1 10 0 1 Shunt resistor for clamp terminal 438920 1 250 0 1 438921 1 100 0 1 438922 1 10 0 1 GM10 Style Number Re...

Страница 6: ...system A unit consisting of a GM10 a GM90PS and a GX90EX Up to six I O modules can be connected to a unit Up to six sub units can be connected via the GX90EX Sub Unit multi unit system A unit consist...

Страница 7: ...not be detected GM10 1 If you want to use the DI of a GX90XD or GX90WD only a single module installed in the GM main unit can be used Do not link modules in a way that violates the specifications Doi...

Страница 8: ...or both do so before setting the date and time Download the following software applications SMARTDAC Standard Hardware Configurator SMARTDAC Standard IP Address Configurator See the list of electroni...

Страница 9: ...e IM 04L55B01 01EN The multi unit system support only cascaded connections If connected in a ring none of the sub units will be identified Link the GX90EX to the left end on a main unit and next to th...

Страница 10: ...e Expand reduce button 2 Click a No The corresponding GM10 is enabled 3 Click Network Config and set the items on the address setting screen For details on the settings see the IP Address Configurator...

Страница 11: ...er 1 and click the button under Channel set Channel number display The Group number 1 Channel set dialog box appears 3 Set AI channel 001 to 0010 to On and click OK The selected channels appear under...

Страница 12: ...unication Reconfiguration dialog box appears click OK The setup data of the connected GM will appear 3 Set the items 4 On the menu bar click the Setting tab and then Send Settings 5 When a Communicati...

Страница 13: ...hese kinds of circumstances wait for at least an hour before using the GM to acclimate it to the surrounding environment Well Ventilated Location To prevent overheating install the GM in a well ventil...

Страница 14: ...ront DIN rail DIN rail Rear of GM Click Check that all the latches are securely fastened to the DIN rail Removing from the DIN Rail 1 Lower the latch on the rear panel of the GM using a flat blade scr...

Страница 15: ...ed For all other signal cables use basic insulated cables dielectric strength of 1390 VAC To prevent electric shock attach the terminal cover after wiring and make sure not to touch the ter minals App...

Страница 16: ...n the thermocouple input take measures to stabilize the temperature at the input terminal Always use the terminal cover Do not use thick wires which may cause large heat dissipation we recommend a cro...

Страница 17: ...ection port and tighten the screw terminal Wiring to a GX90XA Analog Input Module Universal Low withstand voltage relay Electromagnetic relay Current mA type Terminal Diagram CH1 301 201 101 101 102 1...

Страница 18: ...A B B b A 5 DC current input with an external shunt resistor Be careful because the DI wiring is different between level and contact Terminal Arrangement M3 screw terminal CH No Term No Symbol Term N...

Страница 19: ...DI8 COM COM DI9 DI16 COM DI9 DI16 DI1 DI8 COM Wiring direction Wiring direction 11 19 11 19 21 29 21 29 Terminal Arrangement Term No Symbol Term No Symbol 21 DI9 11 DI1 22 DI10 12 DI2 23 DI11 13 DI3...

Страница 20: ...CH2 CH3 CH4 CH5 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH6 CH7 CH8 CH9 CH10 11 20 11 20 21 30 21 30 M3 screw terminal Clamp terminal Wiring direction Wiring direction Terminal Arrangement Term No S...

Страница 21: ...on Internal circuit Connecting to the RS 422 485 Connector C3 option Two wire system Four wire system Electric potential of the shield Shield FG SDB SG SDA RDB RDA Electric potential of the shield Shi...

Страница 22: ...rovide a power switch double pole type on the power supply line to separate the GM from the main power supply Use labels to indicate that this switch is for cutting off the power supply to the GM and...

Страница 23: ...Power On and Off If the power switch of GM GX60 systems under operation be turned on or off carelessly it may result the system down or injury Check the following points before turning on the power s...

Страница 24: ...L Red Lights during an error Setting Switches Dipswitches Use the dipswitches to set the unit number of the expansion module 10 Mbps fixed mode and operation mode master slave Dipswitch Settings Dipsw...