6-30
IM 701240-01E
6.14 Setting the B > Time, B < Time, or B Timeout
(Pulse Width) Trigger (ENHANCED)
<For a description of this function, refer to page 2-20.>
Procedure
1.
Press
MENU
.
2.
Press the
TRIGGER
soft key.
3.
Press the
Trigger Cond. Setup
soft key.
4.
Press the
Select
soft key to select Enhanced.
Setting the Trigger Type
5.
Press the
Type
soft key. The trigger type selection menu appears.
6.
Use the
jog SELECT
to select B > Time, B < Time, or B TimeOut.
Setting the Condition B Pattern
7.
Press the
Set Pattern
soft key. The B > Time trigger, B < Time trigger, and B
TimeOut trigger setup menu appears.
8.
Use
jog SELECT
to select the pattern of each channel (CH1 to CH16)
from H, L, and X. For logic input channels, select Disable or Enable.
Setting the Pulse Width
9.
Use
jog SELECT
to set Time. Pressing
RESET
resets the value to 0.1
µ
s.