2-3
IM 253710-01E
Names and Uses of Parts
2
2.2
Operation Keys, Jog Shuttle, and Rotary Knob
Common to All Functions
CONFIGURATION
ELEMENTS
VOLTAGE
CURRENT
FILTER
1
FILTER
FILTER
FILTER
2
3
4
RES
ET SELECT
CH
8
CH
6
CH
4
CH
2
CH
7
CH
5
CH
3
CH
1
OBSERVATION TIME
TRIG’ D
ACQ
REMOTE
MENU
SHIFT
NULL
CAL
COPY
LOCAL
HELP
MISC
FILE
ZOOM
CURSOR
MATH
DISPLAY
SETUP INPUT MEASURE TRIGGER
ABORT
E S C
SINGLE
START
START/STOP
Soft keys
Press these keys to select the setup
parameter on the displayed menu.
ESC key
Clears and escapes from the current menu.
RESET key
Press this key to reset
the value to default.
SELECT key
Confirms the selection made using the jog shuttle or the set value.
Jog shuttle
Rotate the jog shuttle to select setup parameters or to set values.
The step size increases as the rotation angle of the shuttle ring
increases.
Arrow keys
Moves along the digits of the value that is set by the jog shuttle or
moves the input position of the character string.
SHIFT key
After pressing this key to light the indicator on the upper left corner of the SHIFT
key, press an operation key to display the menu corresponding to the item
indicated below the operation key.
HELP key
Displays help information related to the operation key or soft key
that is pressed after pressing this key. (Section 4.6)
(Shuttle ring)
Set Measurement Mode, Acquisition Conditions of Measured Data, and Trigger
CONFIGURATION
ELEMENTS
VOLTAGE
CURRENT
FILTER
1
FILTER
FILTER
FILTER
2
3
4
RES
ET SELECT
CH
8
CH
6
CH
4
CH
2
CH
7
CH
5
CH
3
CH
1
OBSERVATION TIME
TRIG’ D
ACQ
REMOTE
MENU
SHIFT
NULL
CAL
COPY
LOCAL
HELP
MISC
FILE
ZOOM
CURSOR
MATH
DISPLAY
SETUP INPUT MEASURE TRIGGER
ABORT
E S C
SINGLE
START
START/STOP
SETUP key
Initialize settings, select the measurement mode, select the wiring method, select the PLL source, and
select the number of displayed digits.
(Sections 4.2, 5.1, 5.2, 6.4, 8.1)
START/STOP key
Start/Stop data acquisition. Data can be acquired continuously
by starting the acquisition with this key. (Chapter 4.3)
SINGLE START key
Acquires the data once. (Chapter 4.3)
SHIFT+SINGLE START (ABORT) key
Abort data acquisition. (Chapter 4.3)
CAL key
Perform zero level compensation. (Section 4.4)
NULL key
Activate the NULL function. (Section 4.5)
INPUT key
Set the measurement range, set the PT and CT ratios, set the power coefficient, and select the input
filter. (Sections 5.3 to 5.6)
ROTARY knob
Set the observation time. (Chapter 6.1)
SHIFT+TRIGGER (ACQ) key
Select the record length and time base. (Chapters 6.2, 6.3)
TRIGGER key
Set the trigger. (Chapter 7)
CH key
Turn ON/OFF the waveform display, set the measurement range, set waveform labels, and set the vertical zoom.
(Sections 5.3, 5.4, 9.1, 9.7, 9.8).