YOKOGAWA mR10000 436101 Скачать руководство пользователя страница 3

3

IM 04P01B01-02E

Foreword

Thank you for purchasing the YOKOGAWA 

µ

R10000 Recorder.

This manual describes concisely the operating procedures of the

µ

R10000 Recorder. To ensure correct use, please read this

manual thoroughly before beginning operation.
The following two manuals, in addition to this one, are provided as

manuals for the 

µ

R10000 Recorder. Please read all of them.

Electronic Manuals Provided on the Accompanying CD-ROM

Manual Title

Manual No.

µ

R10000 Recorder User’s Manual

IM 04P01B01-01E

Explains all the functions and procedures of the recorder
excluding the communication functions.

µ

R10000/

µ

R20000 Communication

IM 04P01B01-17E

Interface User’s Manual

Explains the communication functions using Ethernet interface
and the RS-422A/485 communication interface.

Opening the Electronic Manuals

The PDF files of the manuals are provided on the accompanying

CD-ROM. When the CD-ROM is inserted in the PC’s CD-ROM
drive, a list of manuals on the CD-ROM is displayed. Click a

manual title to open the manual. If the list of manuals is not
displayed automatically, open the manual in the My Computer >

4361_4371_manual > English directory.

Notes

The contents of this manual are subject to change without prior
notice as a result of continuing improvements to the

instrument’s performance and functions.

Every effort has been made in the preparation of this manual to

ensure the accuracy of its contents. However, should you have
any questions or find any errors, please contact your nearest

YOKOGAWA dealer as listed on the back cover of this manual.

Copying or reproducing all or any part of the contents of this

manual without the permission of Yokogawa Electric
Corporation is strictly prohibited.

The TCP/IP software of this product and the document
concerning the TCP/IP software have been developed/created

by YOKOGAWA based on the BSD Networking Software,
Release 1 that has been licensed from the University of

California.

Trademarks

All the brands or names of Yokogawa Electric’s products used

in this manual are either trademarks or registered trademarks
of Yokogawa Electric Corporation.

Microsoft, MS-DOS, Windows, Windows NT, and Windows XP
are either registered trademarks or trademarks of Microsoft

Corporation in the United States and/or other countries.

Adobe, Acrobat, and PostScript are trademarks of Adobe

Systems Incorporated.

For purposes of this manual, the TM and ® symbols do not

accompany their respective trademark names or registered
trademark names.

Company and product names that appear in this manual are
trademarks or registered trademarks of their respective

holders.

Revisions

1st Edition

December 2004

2nd Edition

March 2005

3rd Edition

August 2005

4th Edition

September 2006

Safety Precautions

The general safety precautions described here must be observed

during all phases of operation.

Safety Standards and EMC Standards

This recorder conforms to IEC safety class I (provided with terminal
for protective grounding), Installation Category II, Measurement

category II (CAT II), and EN61326-1 (EMC standard), class A (use
in a commercial, industrial, or business environment).

This recorder is designed for indoor use.

About This Manual

This manual should be read by the end user.

Read this manual thoroughly and have a clear understanding of

the product before operation.

This manual explains the functions of the product.

YOKOGAWA does not guarantee that the product will suit a
particular purpose of the user.

Under absolutely no circumstances may the contents of this
manual be transcribed or copied, in part or in whole, without

permission.

The contents of this manual are subject to change without prior

notice.

Every effort has been made in the preparation of this manual to

ensure the accuracy of its contents. However, should you have
any questions or find any errors or omissions, please contact

your nearest YOKOGAWA dealer.

Precautions Related to the Protection, Safety, and Alteration

of the Product

The following safety symbols are used on the product and in

this manual.

“High temperature.”  To avoid injury caused by hot 
surface, do not touch locations where this symbol 
appears.

“Handle with care.”  To avoid injury and damage
to the instrument, the operator must refer to the
explanation in the manual.

Protective ground terminal

AC

DC

For the protection and safe use of the product and the system
controlled by it, be sure to follow the instructions and

precautions on safety that are stated in this manual whenever
you handle the product. Take special note that if you handle the

product in a manner that violate these instructions, the
protection functionality of the product may be damaged or

impaired. In such cases, YOKOGAWA does not guarantee the
quality, performance, function, and safety of the product.

When installing protection and/or safety circuits such as
lightning protection devices and equipment for the product and

control system or designing or installing separate protection
and/or safety circuits for fool-proof design and fail-safe design

of the processes and lines that use the product and the control
system, the user should implement these using additional

devices and equipment.

If you are replacing parts or consumable items of the product,

make sure to use parts specified by YOKOGAWA.

This product is not designed or manufactured to be used in

critical applications that directly affect or threaten human lives.
Such applications include nuclear power equipment, devices

using radioactivity, railway facilities, aviation equipment, air
navigation facilities, aviation facilities, and medical equipment.

If so used, it is the user’s responsibility to include in the system
additional equipment and devices that ensure personnel safety.

Do not modify this product.

4th Edition: September 2006 (YK)
All Rights Reserved, Copyright © 2004 Yokogawa Electric Corporation

Содержание mR10000 436101

Страница 1: ...Operation Guide Yokogawa Electric Corporation IM 04P01B01 02E 4th Edition Models 436101 436102 436103 436104 436106 R10000 Recorder 4 P 1 B 1 0 2 E 0 4...

Страница 2: ...ime 31 Setting the Input Range and Alarm on Measurement Channels 32 Setup Example 1 of Thermocouple Input 32 Setup Example 2 of 1 5V Input and unit 33 Setup Example 3 of 0 to 10 V Input and Unit 35 Se...

Страница 3: ...ses of operation Safety Standards and EMC Standards This recorder conforms to IEC safety class I provided with terminal for protective grounding Installation Category II Measurement category II CAT II...

Страница 4: ...e Software YOKOGAWA makes no warranties regarding the software accompanying this product except those stated in the WARRANTY that is provided separately Use the software on a single PC You must purcha...

Страница 5: ...R Portable type Power cord AS st d7 H5J Portable type Power cord BS st d7 H5H Portable type Power cord GB st d7 M1 Mathematical function N1 Cu10 Cu25 RTD input N2 3 legs isolated RTD4 5 N3 Expansion i...

Страница 6: ...W 1 1 1 1 1 1 1 2 1 1 1 1 1 1 B9901AX B9902AM B9902AN B9902AP B9902AQ B9902AR B9900BX 415920 415921 415922 438920 438921 438922 Note Quantity Model Ribbon cassette Plotter pen Mounting bracket Shunt r...

Страница 7: ...m Changed Users with the same user name cannot be registered Added Language support German and French Added Calibration Correction Added Portable type Added 24 VDC AC power supply operation Added Cust...

Страница 8: ...ages Also the recorder settings can be printed Internal Light A light is provided for easier viewing of the recording area of the chart paper Display Measured values can be displayed numerically or us...

Страница 9: ...display and key panel It lights up the recording area of the chart paper Recording pen Records the measured value Plotter pen Prints various types of information Printer carriage Records measured valu...

Страница 10: ...y while holding down the SHIFT key to switch the character type in reverse order UP DOWN Key Switches the setup item or the value Press this key while holding down the SHIFT key to switch the setup it...

Страница 11: ...In this case let the recorder adjust to the new environment for at least one hour before using it The chart paper may be adversely affected by a rapid change in the ambient temperature and humidity Do...

Страница 12: ...rew temporarily Panel Mounting bracket Attachment screw Fix in place Front Panel Mounting bracket Torque driver flat blade Attachment screw Case In contact with each other The figure shows the case wh...

Страница 13: ...and bottom when mounting the recorders side by side horizontally or right and left when mounting the recorders side by side vertically Side by Side Mounting vertically max 3 units Side by Side Mountin...

Страница 14: ...Length of the stripped section of the wire Approx 5 mm Take measures to prevent noise from entering the measurement circuit Move the measurement circuit away from the power cable power circuit and gro...

Страница 15: ...erminal Clamped input terminal H2 option Dot Model A B b A B b Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 1 Channel 3 Channel 5 Channel 2 Channel 4 Channel 6 A B b Screw input...

Страница 16: ...e terminals of the recorder and or the cable can be damaged In order to prevent tension from being applied directly on the terminals fasten all wiring cables to the rear of the mounting panel Wiring P...

Страница 17: ...e Control Input Terminals 1 to 5 Remote control input terminals C Common Remote control input terminals 1 to 5 are expressed as numbers 1 to 5 in the remote control input settings Transistor input Ope...

Страница 18: ...d a switch or fuse to the ground line Portable Type H5x Option Ensure that the source voltage matches the rated power supply voltage of the instrument before connecting the power cord Connect the powe...

Страница 19: ...N DC AC24V Wiring Procedure Portable Type H5x Option 1 Check that the power switch to the instrument is turned OFF 2 Connect the plug on the accessory power cord to the power supply connector on the...

Страница 20: ...tion M1 option Measurement recording and alarm detection cannot be carried out in this mode Operation mode Power ON Setting mode Data display setup screen Basic Setting mode MENU 1 Display End Store a...

Страница 21: ...key for 3 seconds to enter Setting mode Next hold down both the DISP key and the FUNC key for 3 seconds The Basic Setting mode display appears The top and bottom lines are the setup item and comment...

Страница 22: ...the ESC Key If you press the ESC MENU 1 key the operation is cancelled and the display returns to a higher level menu In other words if you do not show the Setting complete screen the changes you mad...

Страница 23: ...the DISP key to show Ins DISP and then press the DISP key A space for one character is inserted Enter the character Position to insert the character Display Ins DISP Unit ppm CHR Ins DISP Deleting a C...

Страница 24: ...day End time mm h Tag Periodic are not displayed in the default condition To display these items settings must be changed in Basic Setting mode section 5 1 section 6 12 section 6 13 section 5 2 secti...

Страница 25: ...rd Suffix_S P_Adj Pen No Value End End Timeout Duration Keep alive Host Level Suffix primary IP address Subnet mask Primary server Secondary server Gateway Suffix secondary Indicator Increase Decrease...

Страница 26: ...operation Be sure to replace the chart paper ahead of time Loading the Chart Paper 1 Open the door If recording is in progress press the RCD key to stop the recording 2 Remove the chart cassette Gent...

Страница 27: ...holder Chart paper guide The side with the long rectangular holes is the right side 6 Replace the chart cassette back into the recorder Align the left and right projections with the guide grooves of t...

Страница 28: ...s at a Position That Is Not Easily Accessible below 4 Remove the cap from the new felt pen and insert the pen firmly into the pen holder From the top pen 1 red pen 2 green pen 3 blue and pen 4 violet...

Страница 29: ...carriage If you do the carriage position may be offset and the recorder may not print correctly 1 Open the door If recording is in progress press the RCD key to stop the recording 2 Press the FUNC key...

Страница 30: ...e ribbon cassette is difficult turn the ribbon feeding knob in the direction of the arrow to align the ribbon feeding shaft of the cassette with the ribbon feeding shaft of the holder Holder tab Hole...

Страница 31: ...e month position Next press the key four times to change the value from 1 to 5 04 01 17 10 39 47 04 05 17 10 39 47 After change Before change DST Summer On recorders with the version 1 02 or earlier p...

Страница 32: ...2 Press the key with Range shown on the screen Set Range Input range and Displays a description of the setup item Selecting the Channel Range 3 Press the key to set the first channel to 02 and then pr...

Страница 33: ...ecimal point The measured values in the range of 0 0 to 500 0 are recorded in a width of 100 mm on the chart paper 1V 5V 1 5V standard signal 0 0 500 0 Scale left Scale right 1 000 5 000 Span left Spa...

Страница 34: ...ale_L is set to 0 0 Scale_L 0 0 200 00 300 00 Setting Scaling Right 11 Likewise set Scale_R to 500 0 and press the key Scale_R 500 0 2000 0 3000 0 Displays the scaling range The Setting complete scree...

Страница 35: ...es in the range of 0 0 to 400 0 m3 h are recorded in a width of 100 mm on the chart paper 20 V 20 V Linear scaling Measurable range of 20 V 0 0 m3 h 400 0 m3 h Scale left 100 mm Scale right 0 00 V 10...

Страница 36: ...scaling range 11 Press the key to select the desired digit Scale_L 0 00 200 00 300 00 12 Press the key to select space and then press the key Scale_L is set to 0 0 Scale_L 0 0 200 00 300 00 Setting S...

Страница 37: ...ue in the appropriate unit and used as the measured value of the channel Also the low cut function input less than a given measured value is fixed to 0 can be used Skip Disables measurement display pe...

Страница 38: ...s the key to select On and then press the key On Enables the alarm of the selected alarm level Alarm On On Off Displays possible choices 7 Press the key to select H and then press the key The letter H...

Страница 39: ...value R High Limit on Rate of Change Alarm The rate of change of the measured values is checked over a certain time interval An alarm occurs if the rate of change of the measured value in the rising d...

Страница 40: ...le Dot Model The recording examples may appear differently from the actual recording as a result of functional improvements made on the recorder after this manual was written Stopping the Recording Wh...

Страница 41: ...3600 4000 4320 4500 4800 5400 6000 7200 8000 9000 10800 12000 Chart speed on the pen model unit mm h On the dot model enter a vale to set the chart speed The chart speed can be set in the range of 1...

Страница 42: ...ion Nov 09 04 15 00 1 223 5mg cm3 2 437 2 S cm 3 H 591 6 C 4 0 222V 50mm h 14 55 08 00 25mm h 09 52 START 205 ABCDEF 1H3 10 09 1H3 10 05 Printout Description Figure Dot Model Alarm printout Message pr...

Страница 43: ...occurs or releases Time of alarm occurrence release Indicates that there are alarms that are not printed because the alarm printout buffer is full Level number Alarm type Channel No or tag Alarm occu...

Страница 44: ...al can be set to 1 s 2 s 3 s 4 s or 5 s Switching the Displayed Channel Using Keys If Manual switching is specified the channel switches each time the CH UP key is pressed in ascending order All chann...

Страница 45: ...screens Hold the MENU 1 key down for 3 seconds to exit from the data display setup screen Display Types Display types listed below are available besides the types on previous page 1CH digital display...

Страница 46: ...data waiting to be printed in the message printout buffer This is displayed when the settings are changed to use the key lock function It is used to activate or release the key lock Resets the comput...

Страница 47: ...background When printout is complete trend recording resumes If an alarm occurs during the printout the alarm is printed after the recording resumes Starting the List Printout 1 Press the FUNC key 2...

Страница 48: ...or not messages waiting to be printed are temporarily stored in the buffer memory Message printouts are not performed when the chart speed is greater than or equal to 1600 mm h and 101 mm h on the pe...

Страница 49: ...e the key lock function this operation activates or releases the key lock For details on setting the key lock function see section 7 10 Setting the Key Lock Function in the R10000 Recorder User s Manu...

Страница 50: ...s No Yes Setup Item Pen Dot Selectable Range or Selections Default Value Alarm CH 01 to 06 01 Alarm Level 1 2 3 4 1 Alarm Alarm On Off Off Alarm Type H L h l R r T t H Alarm Value Depends on the alarm...

Страница 51: ...le Off s min h day Off Math Aux Zone CH 0A 0B 0C 0D 0E 0F 0G 0J 0K 0M 0N 0P 0A Math Aux Zone Left Right Within the recording span range mm Left 0 Right 100 Math Aux Partial CH 0A 0B 0C 0D 0E 0F 0G 0J...

Страница 52: ...rnal RJC RJC Volt 20000 to 20000 V 0 V Color Channel Dot Model 01 to 06 01 Purple 02 Red Color Color Dot Model Purple Red Green Blue Brown Black 03 Green 04 Blue 05 Brown 06 Black POC POC Pen Model On...

Страница 53: ...Time adjust Record On Off Math start stop M1 Math reset M1 Manual print Alarm ACK Message1 Message2 Message3 Message4 Message5 Priority R_RCD BT1 BatchCMT switch BT1 None M1 BT1 option Computation fu...

Страница 54: ...cters or less Admin admin User1 to 6 user1 to user6 Ethernet LoginSet Password 4 characters or less Administrator 0 User1 to 6 1 to 6 Ethernet Timeout Timeout On Off Off Ethernet Timeout Duration 1 to...

Страница 55: ...al comment Not Use Not Batch MSG format Not Use Not Adjustment Setup Item Pen Dot Selectable Range or Selections Default Value P_Adj P_Adj Dot Model Hysteresis Zero Full Hysteresis Pen Model Zero Full...

Страница 56: ...lotter carriage Chart paper feed motor Display Plotter pen Felt pen PEN ASSY B9902AM B9902AN B9902AP B9902AQ Red Green Blue Violet At a pen speed of 10 cm s 100 000 characters PEN ASSY B9902AR When pr...

Отзывы: