background image

User’s
Manual

Network Solutions Business Division
2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 Japan
Phone: +81-422-52-7179

Facsimile: +81-422-52-6619

1

Please read through this User’s Manual before use for correct handling.

Please keep this User’s Manual for future reference.

Model MU5
Universal Temperature
Converter
(Free Range Type)

CAUTIONARY NOTES FOR SAFE USE
OF THE PRODUCT

This User’s Manual should be carefully read before installing and oper-
ating the product.  The following symbol is used on the product and in
this manual to ensure safe use.

This symbol is displayed on the product when it is neces-
sary to refer to the User’s Manual for information on per-
sonnel and instrument safety.  This symbol is displayed in
the User’s Manual to indicate precautions for avoiding dan-
ger to the operator, such as an electric shock.

The following symbols are used only in this manual.

IMPORTANT

Indicates that operating the hardware or software in a particu-
lar manner may cause damage or result in a system failure.

NOTE

Draws attention to essential information for understanding
the operations and/or functions of the product.

CHECKING PRODUCT SPECIFICATIONS
AND PACKAGED ITEMS

(1) Checking the Model and Product Specifications

Check that the model and specifications indicated on the nameplate
attached to the main unit  are as ordered.

(2) Packaged Items

Check that the package contains the following items:

MU5: 1

RJC sensor (A1167HT): 1
(RJC sensor is not attached for the optional specification
“/RJCN.”)

Spacer (for DIN rail mounting): 1

Range label: 1

User’s Manual (this manual: IM 77J04U05-01E): 1

GENERAL

The MU5 is a plug-in type universal termperature converter that is con-
nected to an IEC/JIS-standard thermocouple, converts the tempera-
ture signals into isolated DC current or DC voltage signals.

IM 77J04U05-01E

Copyright© July 2005

3rd Edition  Oct. 2007 (YK)

MODEL AND SUFFIX CODES

MU5 -01   -       00 /

Model

Output

1: 1 output

Power supply

1: 15-40V DC (Operating range: 12 to 48 V)
6: 100-240 V AC/DC (Operating range: 85 to 264 V)

Input signal

U:Thermocouple, RTD, mV
Z: (Custom order) 

Customized thermocouple or RTD

Output signal

A: 0 to 20 mA DC

Span is 5 mA or more

B: 0 to 5 mA DC

Span is 1 mA or more

1: 

10 to 

+

10 V DC

Span is 0.1 V or more

2: 

100 to 

+

100 mV DC

Span is 10 mV or more

Z: (Custom order) 

Customized current signals or voltage signals

Optional specification

/SN: Without socket
/RJCN: Without RJC sensor

IM 77J04U05-01E

Отзывы: