background image

Technical

Information

FLXA202/FLXA21 2-Wire Analyzer

HART Communication

TI 12A01A02-60E

TI 12A01A02-60E

©Copyright Jul. 2013

4th Edition Jun. 2017

CONTENTS

n

 

What Is HART Communication? ...........................................................2

n

  Downloading and installing DD files

 ....................................................2

l

 

Before using FieldMate

 .....................................................................................2

l

 

Installing the DD File

 .........................................................................................3

l

 

Connecting Setup Tool

 .....................................................................................4

n

  Functions Available via HART Communication

 ..................................4

l

 

Unique Features of HART Communication

 ....................................................5

n

  Setting Non-Available via HART Communication

 ..............................7

n

  Operational Precaution

 ..........................................................................7

l

 

Setting on the FLXA202/FLXA21 and a setup tool (communication tool):

 .7

l

 

Operation with handling all the parameters of the FLXA202/FLXA21:

 .......7

n

  Note for Functions

 ..................................................................................7

l

 

Hold status signal:

 ............................................................................................7

n

  DD Menu Structure for pH Meter Functions 

 

(Device revision 2, DD file revision 1)

...................................................8

n

  DD Menu Structure for SC Meter Functions 

 

(Device revision 2, DD file revision 1)

................................................. 11

n

  DD Menu Structure for ISC Meter Functions 

 

(Device revision 2, DD file revision 1)

.................................................14

n

  DD Menu Structure for DO Meter Functions 

 

(Device revision 2, DD file revision 1)

.................................................17

n

  DD Menu Structure for SENCOM Meter Functions 

 

(Device revision 2, DD file revision 1)

.................................................20

Revision Information

 .....................................................................................24

Содержание FLXA202

Страница 1: ...ational Precaution 7 l Setting on the FLXA202 FLXA21 and a setup tool communication tool 7 l Operation with handling all the parameters of the FLXA202 FLXA21 7 n Note for Functions 7 l Hold status sig...

Страница 2: ...LXA202 FLXA21 needs to be installed in the setup tool The DD file contains the HART communication details and menu configurations specific to the FLXA202 FLXA21 FieldMate contains the latest versions...

Страница 3: ...ed by pressing the on the main display of FLXA202 FLXA21 HOUSING ASSY Module Pdn No BBBB2222 Software Revision 2 11 HART Device Revision 2 Next Revision of FLXA202 FLXA21 software Device revision Figu...

Страница 4: ...power supply and the terminals to which you want to connect the setup tool is 250 ohms or larger Connect the setup tool in parallel with the load resistance It is polarity insensitive n Functions Avai...

Страница 5: ...ddress needs to be set for each device for polling To enable searching for the devices working in the multi drop mode setup tools usually require search address settings too b When the HART setup tool...

Страница 6: ...ON 2 ON Front view with the front panel opened Reboot switch Do not use it Slide switch for HART only Figure 2 FLXA202 Parts names and descriptions 1 ON 2 ON Front view with all wiring covers removed...

Страница 7: ...erational Precaution l Setting on the FLXA202 FLXA21 and a setup tool communication tool When settings are done on a setup tool ex FieldMate don t perform settings on the FLXA202 FLXA21 at the same ti...

Страница 8: ...HOUSING ASSY Logbook Read Logbook Add Logbook Execute Calibration pH Calibration pH Manual 1 Point pH Manual 2 Points pH Manual ITP pH Automatic 1 Point pH Automatic 2 Points pH Sample ORP Calibratio...

Страница 9: ...ts and timing Buffers Free Program Buffer table1 Clear Buffer Table1 Check Values Table1 Buffer table2 Clear Buffer Table2 Check Values Table2 Buffer table3 Clear Buffer Table3 Check Values Table3 Zer...

Страница 10: ...configuration Sensor Fault Sensor Warning Housing Fault Housing Warning Logbook configuration Settings logbook Logbook1 1 Logbook1 2 Erase logbook Calculated data setup Advanced setup Settings Setting...

Страница 11: ...m menu are below the Diagnosis menu n DD Menu Structure for SC Meter Functions Device revision 2 DD file revision 1 Online Sensor 1 Zoom Zoom outputs Zoom sensor Sensor wellness Reset wellness data Ma...

Страница 12: ...rary output Setup Commissioning Measurement setup Configure sensor Temperature settings Temp compensation compensation Method Temp comp 1 TC Temp comp 2 Concentration Concent Table Clear Concentration...

Страница 13: ...k Logbook1 1 Logbook1 2 Erase logbook Calculated data setup Advanced setup Settings Settings Tag Passwords Execute Password Commissioning Password Date Time Date Time Communication HART Display Setup...

Страница 14: ...er Functions Device revision 2 DD file revision 1 Online Sensor 1 Zoom Zoom outputs Zoom sensor Sensor wellness Reset wellness data Maintenance Current Time Last calibrated at Calibration due at Zoom...

Страница 15: ...Concentration Concent Table Clear Concentration Table Check Concentration Values Concentr Table Calibration settings Limits Timing Sensor Diagnosis Settings Sensor diag settings Define heat cycle Outp...

Страница 16: ...ta setup Advanced setup Settings Settings Tag Passwords Execute Password Commissioning Password Date Time Date Time Communication HART Display Setup Dual display Individual display ISC1 ISC2 Trend Tre...

Страница 17: ...data Maintenance Current Time Last calibrated at Calibration due at Zoom device DO module sensor1 HOUSING ASSY Logbook Read Logbook Add Logbook Execute Calibration Air 0 100 Air 100 Water 0 100 Water...

Страница 18: ...g Pressure Comp Cal Sensor diagnosis settings Define Heat cycle Output setup Simulate mA Output Linear mA Table mA Clear AO Table Check AO Values Configure Hold Reset redundant Reset redundant Error c...

Страница 19: ...Individual display DO1 DO2 Trend Trend Graph Screen X axis Y axis Auto Return Adjust contrast Contrast MONITOR Display Change Language Change Language Alarm Fault Warning Sensor 2 Process Values Basi...

Страница 20: ...2 Maintenance Current Time Last calibrated at Calibration due at Zoom device PH module sensor1 HOUSING ASSY SENCOM sensor Model code Fact Date Logbook Read Logbook Add Logbook Execute Calibration pH C...

Страница 21: ...gs pH settings Zero and Slope units Limits and timing Buffers Free Program Buffer table1 Clear Buffer Table1 Check Values Table1 Buffer table2 Clear Buffer Table2 Check Values Table2 Buffer table3 Cle...

Страница 22: ...able mA Clear AO Table Check AO Values Configure Hold Reset redundant Reset redundant Error configuration Sensor Fault Sensor Warning Housing Fault Housing Warning Logbook configuration Settings logbo...

Страница 23: ...X axis Y axis Auto Return Adjust contrast Contrast MONITOR Display Change Language Change Language Alarm Fault Warning Sensor2 Process Values Basic Setup Device information Loop test Review NOTE In th...

Страница 24: ...ition of SENCOM July 2013 1st Edition Newly published based on Appendix 4 of IM 12A01A02 01E 3rd Edition n If you want have more information about Yokogawa products you can visit Yokogawa s homepage a...

Отзывы: