<12. Troubleshooting>
12-1
IM 11M12A01-04E
11th Edition : Jul. 19, 2017-00
12. Troubleshooting
This chapter describes errors and alarms detected by the self-diagnostic function of the
converter. This chapter also describes the check and restoration methods to use when problems
other than the above occur.
12.1 Displays and Measures to Take When
Errors Occur
12.1.1
What is an Error?
An error is detected if any abnormality is generated in the detector or the converter, e.g., in the
cell (sensor) or heater in the detector, or the internal circuits in the converter. If an error occurs,
the converter performs the following:
(1) Stops the supply of power to the heater in the detector to insure system safety.
(2) Causes an error indication in the display to start blinking to notify of an error generation
(Figure 12.1).
(3) Sends an output contact if the error is set up for “Output contact setup” for that contact (refer
to Section 8.4, “Output Contact Setup”).
(4) Changes the analog output status to the one set in “Output hold setting” (refer to Section
8.2, “Output Hold Setting”).
When the display shown in Figure 12.1 appears, pressing the error indication brings up a
description of the error (Figure 12.2). The content of errors that are displayed include those
shown in Table 12.1.
Displayed alternately
Err-01
---------
F12.1E.ai
Figure 12.1
Table 12.1
Types of Errors and Reasons for Occurrence
Error
Type of error
Reason for Occurrence
Error-1 Cell voltage failure
The cell (sensor) voltage signal input to the converter falls below -50 mV.
Error-2 Heater temperature
failure
The heater temperature does not rise during warm-up, or it falls below
730 °C or exceeds 780 °C after warm-up is completed.
Error-3 A/D converter failure
The A/D converter fails in the internal electrical circuit in the converter.
Error-4 Memory failure
Data properly are not written into memory in the internal electrical circuit
in the converter.