<2. Specifications>
2-23
IM 11M12A01-02E 16th Edition : Mar. 19, 2020-00
l
External Dimensions
92
228
253
1600
354
Flow checker
Span gas valve
Zero gas valve
Gas outlet
F2-7E.ai
Zero gas cylinder (6 cylinder): E7050BA
Unit: mm
2.7
Other Equipments
2.7.1
Dust Filter for the Detector (K9471UA)
This filter is used to protect the detector sensor from a corrosive dust components or high velocity
dust in recovery boilers and cement kilns.
Sample gas flow rate is needed to be 1 m/sec or more to replace gas inside zirconia sensor.
l
Standard specification
Applicable detector: Standard-type detector for general use (the sample gas flow should be
approximately perpendicular to the probe.)
Mesh:
30 microns
Material:
Carborundum (Filter), SUS316 (JIS)
Weight:
Approx. 0.2 kg
Part No.
Description
K9471UA
Filter
K9471UX
Tool
Ø
51
32
10
Carborundum filter (SiC)
Detector
Screw
Increasing of insertion length
F3-2E.ai
Attach the filter unit to the tip of
the detector by screwing it clockwise.