YOKOGAWA DLM5034 Скачать руководство пользователя страница 1

Operation

Guide

Workflow

Measuring the Waveform

Use vertical cursors to measure the time and voltage of the displayed waveform.

Displaying the Waveform

Use auto setup to display the input signal (the instrument’s probe compensation signal).

Saving the Waveform Screen Image

Save the displayed screen image as data.

Changing the Waveform Display Conditions

Change the vertical axis, horizontal axis, and edge trigger settings.

Using the Instrument according to the Workflow

What to Prepare

• The instrument. This guide explains the DLM5058 as an example.

• Power cord that complies with the standard specified by the country or region that the instrument

will be used in

• Included passive probe (701937)

1

• Manual

Printed

Operation Guide

IM DLM5058-04EN

This document. Explains the basic operations of this 

instrument in steps.

Getting Started Guide

IM DLM5058-03EN

Explains the handling precautions and warnings of 

this instrument, how to connect the power supply, how 

to turn the power switch on and off, how to connect 

probes, how to correct the probe phases, and other 

common operations.

Before using the instrument, be sure to read the 

handling precautions and warnings.

PDF data

(contained in 

the CD)

Features Guide & Users 

Manual.pdf

Features Guide (IM DLM5058-01EN) and User’s 

Manual (IM DLM5058-02EN). Explain the features of 

this instrument and how to configure them.

• Adjustment screwdriver (used in the phase correction of probes)

2

DLM5000

Power cord

Passive probe

1

Manual

Adjustment 

screwdriver

2

1  Miniature passive probe 701949 is included with options /E2 and /E3.

2  Use a non-metallic adjustment driver that matches the dimensions of the probe phase 

adjustment hole.

L

W

Driver bit dimensions (reference)

Tip shape: – (minus)

Tip thickness (W): 0.4 mm to 0.5 mm

Tip width (W): 1.3 mm to 2.5 mm

Measurement Preparation

1.

 

Turn on the power switch.

See section 2.3, “Connecting the Power Supply and Turning the Power Switch On and Off,” in 

the Getting Started Guide (IM DLM5058-03EN).

2.

 

Connect a probe to the instrument’s input terminal (CH1).

See section 2.4, “Connecting Probes,” in the Getting Started Guide.

3.

 

Correct the probe phase.

See section 2.5, “Correcting a Probe Phase,” in the Getting Started Guide.

 

Probe compensation 

signal output terminal

Functional ground 

terminal

Phase adjustment 

hole

This operation guide explains the basic operations of this instrument. In this guide, operations are 

described in steps from “Preparation” to “Displaying Waveforms,” “Measuring Waveforms,” and “Saving 

Screen Captures.”

For handling precautions and warnings of this instrument, read the Getting Started Guide (IM 

DLM5058-03EN) thoroughly, and use the instrument properly.

IM DLM5058-04EN

1st Edition

Displaying the Waveform

Here, use the instrument’s probe compensation signal (frequency: approx. 1 kHz, amplitude: approx. 1 V, 

square wave signal) for the input signal.

1. 

Press 

AUTO

 to execute auto setup.

1

Voltage scale: 500 mV/div

When you execute auto setup, the voltage scale (V/div), time scale (Time/div), trigger level, and the like 

are automatically set to values suitable for the input signal.

*

* The auto setup feature may not work properly for signals that include a DC component or high-

frequency components.

To measure the voltage with high accuracy, adjust the vertical scale so that the input signal is 

measured with the largest possible amplitude.

Changing the Vertical Axis Settings

Change the vertical scale (voltage sensitivity) from 500 mV/div to 200 mV/div to increase the waveform 

amplitude. Setting the voltage sensitivity means setting the voltage per grid division (V/div).

1. 

Press 

CH

 (

1

).

2. 

Use the 

SCALE

 knob to change the voltage sensitivity to 200 mV/div.

Voltage sensitivity: 200 mV/div

The waveform is expanded vertically 

causing a portion of the waveform to 

go off the screen.

1

2

Measurements may not be performed correctly in this condition. Lower the vertical position to that the 

entire waveform can be seen.

3. 

Use the 

POSITION

 knob to move the vertical position down by 2 divisions.

3

2 div

Vertical 

position (     )

The ground level 

(    ) also moves 

along with the 

waveform.

Lowering the vertical position causes 

the entire waveform to be seen.

For details on the vertical axis, see chapter 1, “Vertical Axis (Analog Signal),” in the Features 

Guide (IM DLM5058-01EN).

DLM5034, DLM5038, DLM5054, DLM5058

Mixed Signal Oscilloscope

Operation Guide

1st Edition: September 2020 (YMI)

All Rights Reserved, Copyright © 2020, Yokogawa Test & Measurement Corporation

Printed in Japan

IM DLM5058-04EN  1/2

nbn @ nbn. at 

www. nbn. at

Riesstraße 146, 8010 Graz 

Tel. +43 316 40 28 05  |  Fax +43 316 40 25 06

nbn Austria GmbH

Отзывы: