5-181
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:BRATe
Function
Sets or queries the FlexRay bus signal analysis
bit rate (data transfer rate).
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:BRATe {<NRf>}
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:BRATe?
<x> = 1 to 4
<NRf> = 2500000, 5000000, 10000000
Example
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BR
ATE 5000000
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BR
ATE?
-> :SERIALBUS1:FLEXRAY:ANALYZE:
SETUP:BRATE 5000000
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:SOURce
Function
Sets or queries the source signal for FlexRay bus
signal analysis.
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:SOURce {<NRf>|MATH<y>}
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:SOURce?
<x> = 1 to 4
<NRf> = 1 to 8
<y> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:SO
URCE 1
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:SO
URCE?
-> :SERIALBUS1:FLEXRAY:ANALYZE:
SETUP:SOURCE 1
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:SPOint
Function
Sets or queries the FlexRay bus signal sample
point.
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:SPOint {<NRf>}
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:SPOint?
<x> = 1 to 4
<NRf> = 4, 5, or 6
Example
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:
SPOINT 5
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:
SPOINT?
-> :SERIALBUS1:FLEXRAY:ANALYZE:
SETUP:SPOINT 5
:SERialbus<x>:FLEXray:DETail?
Function
Queries all FlexRay bus signal analysis result list
settings.
Syntax
:SERialbus<x>:FLEXray:DETail?
<x> = 1 to 4
:SERialbus<x>:FLEXray:DETail:DISPlay
Function
Sets or queries the display mode for the FlexRay
bus signal analysis result list.
Syntax
:SERialbus<x>:FLEXray:DETail:DISPl
ay {FULL|LOWer|UPPer}
:SERialbus<x>:FLEXray:DETail:DISPl
ay?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:DETAIL:DISPL
AY FULL
:SERIALBUS1:FLEXRAY:DETAIL:DISPLAY?
-> :SERIALBUS1:FLEXRAY:DETAIL:DISPL
AY FULL
:SERialbus<x>:FLEXray:DETail:LIST:IT
EM?
Function
Queries all items that will be displayed in the
FlexRay bus signal analysis result list.
Syntax
:SERialbus<x>:FLEXray:DETail:LIST:IT
EM?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:DETAIL:LIST:IT
EM?
-> :SERIALBUS1:FLEXRAY:DETAIL:LIST:
ITEM "No.,Time(ms),S/D,IND,ID,Len,CC
,Data,Information,"
:SERialbus<x>:FLEXray:DETail:LIST:VA
Lue?
Function
Queries all of the data for the specified analysis
number in the FlexRay bus signal analysis result
list.
Syntax
:SERialbus<x>:FLEXray:DETail:LIST:VA
Lue? {<NRf>|MAXimum|MINimum}
<x> = 1 to 4
<NRf> = See the DLM4000 Features Guide for
this information.
Example
:SERIALBUS1:FLEXRAY:DETAIL:LIST:VAL
UE? 0
-> :SERIALBUS1:FLEXRAY:DETAIL:LIST:V
ALUE "0,−0.0001968,S,1111, 4, 4, 2,
01 02 03 04 05 06 07 08,,"
:SERialbus<x>:FLEXray:SEARch?
Function
Queries all FlexRay bus signal search settings.
Syntax
:SERialbus<x>:FLEXray:SEARch?
<x> = 1 to 4
:SERialbus<x>:FLEXray:SEARch:ABORt
Function
Aborts the FlexRay bus signal search.
Syntax
:SERialbus<x>:FLEXray:SEARch:ABORt
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:ABORT
:SERialbus<x>:FLEXray:SEARch:EXECute
Function
Executes a FlexRay bus signal search.
Syntax
:SERialbus<x>:FLEXray:SEARch:EXECute
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:EXECUTE