47
IM 701450-61E
:PANalyze?
Function
Queries all settings related to the input/output of
power analysis.
Syntax
:PANalyze?
Example
:PANALYZE? -> :PANALYZE:PWR1:
MODE 1;U:PROBE 10;:PANALYZE:PWR1:I:
PROBE C10;:PANALYZE:PWR2:MODE 1;U:
PROBE 10;:PANALYZE:PWR2:I:
PROBE C10;:PANALYZE:PWR3:MODE 1;U:
PROBE 10;:PANALYZE:PWR3:I:
PROBE C10;:PANALYZE:MATH1:MODE 1;:
PANALYZE:MATH2:MODE 1
:PANalyze:JUMP
Function
Jumps from the power analysis setup screen to
the selected setup screen.
Syntax
:PANalyze:JUMP {DESKew|MATH|
MEASure}
Example
:PANALYZE:JUMP DESKEW
:PANalyze:MATH<x>?
Function
Queries all settings related to the computed
waveform MATH<x> of power analysis.
Syntax
:PANalyze:MATH<x>?
<x> = 1 to 2
Example
:PANALYZE:PWR1:I:PROBE? ->
:PANALYZE:PWR1:I:PROBE C10
:PANalyze:MATH<x>:MODE
Function
Enables/Disables the computed waveform
MATH<x> of power analysis or queries the
current setting.
Syntax
:PANalyze:MATH<x>:MODE {<Boolean>}
:PANalyze:MATH<x>:MODE?
<x> = 1 to 2
Example
:PANALYZE:PWR1:MODE ON
:PANALYZE:PWR1:MODE? ->
:PANALYZE:PWR1:MODE 1
:PANalyze:PWR<x>?
Function
Queries all settings related to the power
analysis target PWR<x>.
Syntax
:PANalyze:PWR<x>?
<x> = 1 to 3 (1 or 2 on the DL7440)
Example
:PANALYZE:PWR1? ->
:PANALYZE:PWR1:MODE 1;U:PROBE 10;:
PANALYZE:PWR1:I:PROBE C10
:PANalyze:PWR<x>:MODE
Function
Enables/Disables the power analysis target
PWR<x> or queries the current setting.
Syntax
:PANalyze:PWR<x>:MODE {<Boolean>}
:PANalyze:PWR<x>:MODE?
<x> = 1 to 3 (1 or 2 on the DL7440)
Example
:PANALYZE:PWR1:MODE ON
:PANALYZE:PWR1:MODE? ->
:PANALYZE:PWR1:MODE 1
:PANalyze:PWR<x>:U?
Function
Queries all settings related to the voltage input
channel of the power analysis target PWR<x>.
Syntax
:PANalyze:PWR<x>:U?
<x> = 1 to 3 (1 or 2 on the DL7440)
Example
:PANALYZE:PWR1:U? ->
:PANALYZE:PWR1:U:PROBE 10
:PANalyze:PWR<x>:U:PROBe
Function
Sets the probe attenuation of the voltage input
channel of the power analysis target PWR<x>
or queries the current setting.
Syntax
:PANalyze:PWR<x>:U:PROBe {<NRf>}
:PANalyze:PWR<x>:U:PROBe?
<x> = 1 to 3 (1 or 2 on the DL7440)
<NRf> = 1,10,100,1000
Example
:PANALYZE:PWR1:U:PROBE 100
:PANALYZE:PWR1:U:PROBE? ->
:PANALYZE:PWR1:U:PROBE 100
:PANalyze:PWR<x>:I?
Function
Queries all settings related to the current input
channel of the power analysis target PWR<x>.
Syntax
:PANalyze:PWR<x>:I?
<x> = 1 to 3 (1 or 2 on the DL7440)
Example
:PANALYZE:PWR1:I:PROBE? ->
:PANALYZE:PWR1:I:PROBE C10
:PANalyze:PWR<x>:I:PROBe
Function
Sets the current-to-voltage conversion ratio of
the current input channel of the power analysis
target PWR<x> or queries the current setting.
Syntax
:PANalyze:PWR<x>:I:PROBe {C10|C100}
:PANalyze:PWR<x>:I:PROBe?
<x> = 1 to 3 (1 or 2 on the DL7440)
Example
:PANALYZE:PWR1:I:PROBE C100
:PANALYZE:PWR1:I:PROBE? ->
:PANALYZE:PWR1:I:PROBE C100
12 Communication Commands