<9. GENERAL SPECIFICATIONS>
9-3
IM 01F06F00-01EN
Functional Specifications:
Functional specifications for Fieldbus communication conform to the standard specifications (H1) of F
OUNDATION
fieldbus.
F
OUNDATION
Fieldbus specifications (ITK 5.0.1) grant the interoperability of the field instruments.
Function blocks:
Block name
Number
Execution time
Note
AI
3
29 ms
AI1: Monitors the fow rate and totalized flow rate; AI2: Monitors the temperature
for a model with the multi-variable type option; AI3: volumetric flow input for mass
flowrate calculation of AR.
DI
2
25 ms
Flow and temperature limit switches
AR
1
40 ms
Mass flow calculation
IT
1
40 ms
Integrator block integrates a variable as a function of the time or accumulates the
counts
PID
1
40 ms
Applicable when LC1 option is specified
9.2 Model and Suffix Codes
DY
-F
-
/
-N
DYA-F
/
F: digital communication (F
OUNDATION
Fieldbus protocol)
N: Remote type detector