11.1 Specifications
Item
Specifications
Applicable fiber
SM, GI (50/125
µ
m, 62.5/125
µ
m), Large core size fibers (core diameter of up to 800 µm)
Measurement wavelength range
1
350 to 1200 nm
Span
1
0.5 nm to 850 nm (entire wavelength range), 0 nm
Wavelength accuracy
1, 2
±0.2 nm (400 to 1100 nm)
±0.05 nm (633 nm)
Wavelength resolution setting
1, 3
0.02, 0.05, 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 nm, and 0.01 nm (at a measured wavelength
range of 400 to 470 nm)
Measurement data point
101 to 50001, AUTO
(Wavelength sampling points)
Wavelength sampling resolution
0.001 nm minimum
Level sensitivity setting
NORM_HOLD, NORM_AUTO, NORMAL, MID, HIGH1, HIGH2 and HIGH3
High dynamic range mode
SWITCH (Sensitivity: MID, HIGH1, HIGH2, HIGH3)
Level sensitivity
4, 5
-80 dBm (500 to 1000 nm, resolution: 0.2 nm or more, measuring sensitivity: HIGH3)
-60 dBm (400 to 500 nm, resolution: 0.2 nm or more, measurement sensitivity: HIGH3)
-60 dBm (1000 to 1100 nm, resolution: 0.2 nm or more, measurement sensitivity:HIGH3)
Level accuracy
4
±1.0 dB (850 nm, -20 dBm, resolution: 0.2 nm or more, sensitivity setting: MID, HIGH1,
HIGH2, HIGH3) (when using an (MFD 5 µm @850 nm, NA 0.14 (typ.) SMF)
Leval linearity
4
±0.2 dB (input level: -40 to +0 dBm, measuring sensitivity: HIGH1, HIGH2, HIGH3)
Safe max. input power
4
+20 dBm (total light input power at 550 to 1100 nm)
+10 dBm (total light input power at 400 to 550 nm)
Dynamic range
1
60 dB or more (633 nm, ±0.5 nm of peak wavelength, resolution: 0.02 nm)
Sweep time
1, 6
0.5 s (NORM_AUTO), 1 s (NORMAL)
2 s (MID)
5 s (HIGH1), 20 s (HIGH2), 75 s (HIGH3)
Function
Automatic measurement
Program function (64 programs, 200 steps)
Setting of measuring conditions
Center wavelength, span, wavelength sampling points, wavelength resolution,
measurement sensitivity, high dynamic mode, averaging times (1 to 999), sweep (single,
repeat, AUTO: automatically sets measuring conditions), sweep between marker function,
pulse light measurement function, smoothing function, external trigger measurement
function, sweep status output function, analog output function, air/vacuum wavelength
measurement function, template-based Pass/Fail judgment function
Display
Level scale (0.1 to 10 dB/div., linear scale), level subscale (0.1 to 10 dB/div., linear scale),
reference level display, vertical axis DIV display (8, 10, 12), horizontal axis wavelength/
frequency display, horizontal axis scale zoom in/out display, measuring conditions display,
noise mask display, data table display, label display, split screen display, percent display,
power density (dB/nm) display, dB/km display, template display
Traces
Simultaneous display of 7 independent traces, write mode fixed mode setting, show/hide
setting, max/min value detection display, calculation between traces display, roll averaging
display (sweep average) (2 to 100 times), normalized display, curve fit display (peak curve
fit, marker curve fit), trace copy function, trace clear functionfunction, saving/loading all
trace function
Marker/Search
Delta markers (1024 points maximum), vertical/horizontal line markers, peak search,
bottom search, auto search (ON/OFF), search between vertical axis line markers, search
within zoom area
Analysis
Spectral width analysis (threshold, envelope, RMS, Peak RMS, notch), OSNR (WDM)
analysis, chromaticity coordinate analysis (COLOR analysis), filter peak/bottom analysis,
DFB-LD analysis, FP-LD analysis, LED analysis, SMSR analysis, power analysis, PMD
analysis, Pass/Fail judgment from template, auto analysis, analysis between vertical axis
line markers, analysis within the zoom area
Other
Auto alignment function with built-in reference light source
Chapter 11 Specifications