5-16
IM AQ1300-01EN
5.7 Controlling the Other Device Remotely
Procedure
Follow the procedure in section 5.4 to display the Auto Setup screen.
Press the
Remote Control
soft key to display the following screen.
Stop remote control.
Set the test direction.
(M => S, M <= S, M <=> S, M <=> LOOP )
Re-establish remote control.
Explanation
Remote Disconnect
Press this soft key to stop remote control from the master. When you press this key, the remote
communication between the master and the slave through the test interface is cut off.
Remote Reconnect
Press this soft key after the remote connection has been cut off to reconnect from the master. When
you press this key, the remote communication between the master and the slave through the test
interface is re-established.
Direction
In Auto(Remote) mode, you can specify the direction in which remote testing is performed.
Non-Loopback Testing
• M => S: Testing is performed in the direction of the master to the slave.
• M <= S: Testing is performed in the direction of the slave to the master.
• M <=> S : Testing is performed in both directions: from the master to the slave and from the
slave to the master.
Loopback Testing
• M <=> LOOP: When the slave is set to Loopback Test mode, the direction setting is fixed at
M <=> LOOP.