10-18
IM 701730-01E
Setting the Status Determination Pattern and Search Start Point
13.
Use
jog shuttle & SELECT
to select the preset status determination pattern of
sixty-four points from A to D (Pattern box).
14.
As necessary, use
jog shuttle & SELECT
to change the status determination
pattern A to D by selecting the status of points 0 to 63 from H, L, and X.
If Clear Pattern is executed using jog shuttle & SELECT, all points are set to X.
15.
Use
jog shuttle & SELECT
to set the search start point (Start Point box).
Select the preset status determination pattern of sixty-four
points from A to D.
As necessary, change the status determination pattern A to
D by selecting the status of points 0 to 63 from H, L, and X.
All points are set to X.
Set the search start point.
16.
Press
ESC
. The Setup dialog box closes.
Selecting the Window for Displaying the Searched Waveform (Zoom Waveform
Display Frame)
17.
The procedure is the same as step 12 on page 10-15.
Executing/Aborting the Search
18.
The procedure is the same as step 13 and 14 on page 10-15.
Redisplaying the Detected Waveforms
19.
The procedure is the same as step 15 and 16 on page 10-16.
Changing the Zoom Rate and Zoom Position of the Detected Waveforms
20.
Change the zoom rate and zoom position of the waveform according to the
procedures given in section 8.4.
Parallel Pattern (Parallel Status Pattern) Search
1.
Press
SHIFT+ZOOM (SEARCH)
. The SEARCH menu appears.
Selecting the Parallel Pattern Search Method
2.
Press the
Type
soft key. The Type menu appears.
3.
Press the
Parallel Pattern
soft key.
Setting the Search Condition
4.
Press the
Setup
soft key. The Setup dialog box opens.
10.4 Searching Waveforms Using the Search and Zoom Function