15
2.5 Advanced Setup
:
Set Pan direction of rotation
Off
Do not reverse
Pan
Reverse
On
Reverse
Set Tilt direction of rotation
Off
Do not reverse
Tilt
Reverse
On
Reverse
Set whether the fixture detects Pan/Tilt out-of-step
and corrects
Off
Do not correct position after out of step
Optocoupl
er Revise
On
Automatically correct position after out of
step and record out of step fault.
Set the position of zero point of Pan
Pan Offset
4-150
Set the position of zero point of Tilt
Tilt Offset
4-48
When setting no DMX signal of the signal,the
machine’s output state:
Off
When no signal,all motors and light source
return to the position and state of reset
complete.
Data-hold
On
When no signal,keep the last frame of DMX
data output.
Set the bulb’s first open mode after power on.
Light
Up
Mode
Light up
after
power
Turn on the light bulb first and reset the
lamp after 30 seconds.
Содержание YR-380BSW