A.17 V/f Pattern Default Values
The following tables show the V/f pattern setting default values depending on the control mode (A1-02) and the V/f pattern
selection (E1-03 in V/f Control).
Table A.4 E1-03 V/f Pattern Settings for Drive Capacity: Model 4
o
0011
No.
Unit
V/f Control
E1-03
-
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
<1>
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0
180.0
60.0
E1-05
<2>
V
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
230.0
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
60.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
30.0
E1-08
<2>
V
15.0
15.0
15.0
15.0
35.0
50.0
35.0
50.0
19.0
24.0
19.0
24.0
15.0
15.0
15.0
57.5
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.5
E1-10
<2>
V
9.0
9.0
9.0
9.0
8.0
9.0
8.0
9.0
11.0
13.0
11.0
15.0
9.0
9.0
9.0
10.2
<1> This value determines the default values for E1-04 through E1-10.
<2> Values shown here are specific to 200 V class drives. Double the value for 400 V class drives.
Table A.5 E1-03 V/f Pattern Settings for Drive Capacity: Models 2
o
0028 to 2
o
0154 and 4
o
0014 to 4
o
0096
No.
Unit
V/f Control
E1-03
-
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
<1>
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0
180.0
60.0
E1-05
<2>
V
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
230.0
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
60.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
30.0
E1-08
<2>
V
14.0
14.0
14.0
14.0
35.0
50.0
35.0
50.0
18.0
23.0
18.0
23.0
14.0
14.0
14.0
57.5
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.5
E1-10
<2>
V
7.0
7.0
7.0
7.0
6.0
7.0
6.0
7.0
9.0
11.0
9.0
13.0
7.0
7.0
7.0
8.1
<1> This value determines the default values for E1-04 through E1-10.
<2> Values shown here are specific to 200 V class drives. Double the value for 400 V class drives.
Table A.6 E1-03 V/f Pattern Settings for Drive Capacity: Models 2
o
0192, 2
o
0248, and 4
o
0124 to 4
o
0414
No.
Unit
V/f Control
E1-03
-
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
<1>
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0
180.0
60.0
E1-05
<2>
V
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
230.0
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
60.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
30.0
E1-08
<2>
V
12.0
12.0
12.0
12.0
35.0
50.0
35.0
50.0
15.0
20.0
15.0
20.0
12.0
12.0
12.0
57.5
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.5
E1-10
<2>
V
6.0
6.0
6.0
6.0
5.0
6.0
5.0
6.0
7.0
9.0
7.0
11.0
6.0
6.0
6.0
6.9
<1> This value determines the default values for E1-04 through E1-10.
<2> Values shown here are specific to 200 V class drives. Double the value for 400 V class drives.