No.
(Addr.
Hex)
Name
LCD Display
Description
Values
Page
E1-04
(303)
Maximum Output
Frequency
Max Frequency
These parameters are only applicable when E1-03 is set to F.
To set linear V/f characteristics, set the same values for E1-07
and E1-09.
In this case, the setting for E1-08 will be disregarded. Ensure
that the four frequencies are set according to these rules:
E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04
Output Voltage (V)
Frequency (Hz)
E1-05
E1-12
E1-13
E1-08
E1-10
E1-09
E1-07 E1-06 E1-11 E1-04
Note:
E1-07, E1-08, and E1-10 to E1-13 are not
available in OLV/PM control mode.
Default: 60.0 Hz
Min.: 40.0 Hz
Max.: 240.0 Hz
E1-05
(304)
Maximum Voltage
Max Voltage
Default: 575 V
Min.: 0.0 V
Max.: 733.1 V
E1-06
(305)
Base Frequency
Base Frequency
Default: 60.0 Hz
Min.: 0.0 Hz
Max.: 240.0 Hz
E1-07
(306)
Middle Output
Frequency
Mid Frequency A
Default: 30.0 Hz
Min.: 0.0
Max.: 240.0
E1-08
(307)
Middle Output
Frequency Voltage
Mid Voltage A
Default: 143.8 V
Min.: 0.0
Max.: 733.1
E1-09
(308)
Minimum Output
Frequency
Min Frequency
Min.: 0.0 Hz
Max.: 240.0 Hz
E1-10
(309)
Minimum Output
Frequency Voltage
Min Voltage
Default: 25.9 V
Min.: 0.0 V
Max.: 733.1 V
E1-11
(30A)
Middle Output
Frequency 2
Mid Frequency B
Default: 0.0 Hz
Min.: 0.0
Max.: 240.0
E1-12
(30B)
Middle Output
Frequency Voltage 2
Mid Voltage B
Default: 0.0 V
Min.: 0.0
Max.: 733.1
E1-13
(30C)
Base Voltage
Base Voltage
Min.: 0.0
Max.: 733.1
<1> Parameter setting value is not reset to the default value when the drive is initialized.
<2> Default setting is dependent on parameter A1-02, Control Mode Selection.
<3> Default setting is dependent on parameter o2-04, Drive Model Selection.
<4> When Auto-Tuning is performed, E1-13 and E1-05 will be set to the same value.
<5> Parameter ignored when E1-11 (Motor 1 Mid Output Frequency 2) and E1-12 (Motor 1 Mid Output Frequency Voltage 2) are set to 0.0.
u
E2: Motor Parameters
No.
(Addr.
Hex)
Name
LCD Display
Description
Values
Page
E2-01
(30E)
Motor Rated Current
Motor Rated FLA
Sets the motor nameplate full load current in amps.
Automatically set during Auto-Tuning.
Min.: 10% of
drive rated
current
Max.: 200% of
drive rated
current
E2-02
(30F)
Motor Rated Slip
Motor Rated Slip
Sets the motor rated slip. Automatically set during
Auto-Tuning.
Min.: 0.00 Hz
Max.: 20.00 Hz
E2-03
(310)
Motor No-Load Current No-Load Current
Sets the no-load current for the motor. Automatically set during
Auto-Tuning.
Min.: 0 A
Max.: E2-01
A.7 E: Motor Parameters
YASKAWA SIEP YAIZ1U 03B YASKAWA AC Drive – Z1000 Programming Manual
199