15.2 Procedure of Welding Current Calibration
15-2
HW0480311
HW0480311
15.2
Procedure of Welding Current Calibration
The main procedures of welding current calibration are as follows;
1.
Starting up the welding source in the Welding Current Calibration mode
2.
Welding by the current calibration 1
3.
Confirming the result of calibration 1
4.
Welding by the current calibration 2
5.
Confirming the result of calibration 2
6.
Saving the conditions of calibration (results)
7.
Returning to the usual welding mode
The following explain the procedures of welding current calibration in detail.
1.
Starting up the welding source in the Welding Current Calibration mode
(1) Turn ON the welding source main power while pressing the "PRM Select" button to
start up the welding source in the Welding Current Calibration mode.
If the 7-segment LED indicators of "V" and "A" on the panel blink, the mode is being
set to the Welding Current Calibration mode.
2.
Welding by the current calibration 1
(1) If the 7-segment LED indicators of "V" and "A" on the panel blink, the current cali-
bration 1 is in standby state.
The welding current calibration cannot be performed without selecting a user file. Be sure
to select one of user files No.1, No.2, or No.3 beforehand, save the conditions (see " 4.2.6
Saving Welding Conditions "), and turn ON the welding source with the user file selected.
Wire m/min
Type
ON
OFF
Power
Warning
Search
Record
Gas
Common PRM Select
PRM Select
PRM Set
Weld, Type
File No.1
File No.2
File No.3
User File Select
L
R
Auto Adjustment
/Individual
Auto Adj.
V
A
V
A
Wire m/min
Type
The 7-segment LED indicators of "V" and "A" starts blinking.
NOTE
V
A
Wire m/min
Type
112/129