5
Deployment I/O periphery
5.1 Overview
n
On this CPU the connectors for digital respectively analog signal and
Technological
functions
are combined in a one casing.
n
The project engineering happens in the Siemens SIMATIC Manager as Siemens CPU
314C-2 PN/DP (314-6EH04-0AB0 V3.3). Here the CPU M13-CCF0000 is parameter-
ized via the
‘Properties’
dialog of the Siemens CPU 314C-2 PN/DP
(314-6EH04-0AB0 V3.3).
n
For parametrization of the digital I/O periphery and the
technological functions
the
corresponding sub modules of the CPU 314C-2 PN/DP (314-6EH04-0AB0 V3.3) is to
be used.
n
The controlling of the operating modes of the
technological functions
happens by
means of handling blocks of the user program.
n
The integrated I/Os of the CPU may be used for
technological functions
or as
standard periphery.
n
Technological functions
and standard periphery may be used simultaneously with
appropriate hardware.
n
Read access to inputs used by
technological functions
is possible.
n
Write access to used outputs is not possible.
n
Chap. 5.3 ‘Analog input’ page 108
–
AI 2xUx12Bit (0 ... 10V)
–
The analog channels of the module are not isolated to the electronic power
supply.
–
The analog part has no status indication
n
Chap. 5.4 ‘Digital input’ page 111
–
DI 16xDC 24V
–
Interrupt functions parameterizable
–
Status indication via LEDs
n
Chap. 5.5 ‘Digital output’ page 115
–
DO 12xDC 24V, 0.5A
–
Status indication via LEDs
n
–
4 channels
–
Count once
–
Count continuously
–
Count Periodically
–
Control by the user program (SFB 47)
n
Chap. 5.7 ‘Frequency measurement’ page 140
–
4 channels
–
Control by the user program (SFB 48)
n
Chap. 5.8 ‘Pulse width modulation - PWM’ page 146
–
2 channels
–
Control by the user program (SFB 49)
n
Chap. 5.9 ‘Pulse train’ page 151
–
2 channels
–
Control by the user program (SFB 49)
Project engineering and
parametrization
I/O periphery
Technological functions
VIPA System MICRO
Deployment I/O periphery
Overview
HB400 | CPU | M13-CCF0000 | en | 18-50
106