6. Parameter list
Parameter
No.
Description
Factory
Setting
n001
Parameter Access
1
n002
Control Mode Selection
0
(Note1, 4)
n003
RUN Command
0
n004
Frequency Reference
Selection
1
n005
Stopping Method Selection
0
n006
Reverse Run Prohibit
0
n007
Stop Key Selection
0
n008
Frequency Reference
Selection in Local Mode
1
n009
Frequency Reference Setting
Method From Digital Opera-
tor
0
n010
Detecting Fault Contact of
Digital Operator
0
n011
Max. Output Frequency
50.0Hz
n012
Max. Voltage
200V
(Note 2)
n013
Max. Voltage Output
Frequency
50.0Hz
n014
Mid. Output Frequency
1.3Hz
(Note 4)
n015
Mid. Output Frequency
Voltage
12.0V
(Note 2,4)
n016
Min. Output Frequency
1.3Hz
(Note 4)
n017
Min. Output Frequency
Voltage
12.0V
(Note 2,4)
n018
Selecting Setting Unit for Ac-
celeration/deceleration Time
0
n019
Acceleration Time 1
10.0s
n020
Deceleration Time 1
10.0s
n021
Acceleration Time 2
10.0s
n022
Deceleration Time 2
10.0s
n023
S-curve Selection
0
n024
Frequency Reference 1
(Master Frequency
Reference)
6.00Hz
n025
Frequency Reference 2
0.00Hz
n026
Frequency Reference 3
0.00Hz
n027
Frequency Reference 4
0.00Hz
n028
Frequency Reference 5
0.00Hz
n029
Frequency Reference 6
0.00Hz
n030
Frequency Reference 7
0.00Hz
Parameter